Daikin FTX50GV1B [4/131] Part 6 service diagnosis 9

Daikin FTX71GV1B [4/131] Part 6 service diagnosis 9
SiBE041029_A
iii Table of Contents
Part 6 Service Diagnosis............................................................. 49
1. Troubleshooting with LED .....................................................................51
1.1 Indoor Unit..............................................................................................51
1.2 Outdoor Unit ...........................................................................................51
2. Problem Symptoms and Measures .......................................................52
3. Service Check Function ........................................................................53
4. Troubleshooting ....................................................................................56
4.1 Error Codes and Description ..................................................................56
4.2 Indoor Unit PCB Abnormality .................................................................57
4.3 Freeze-up Protection Control or Heating Peak-cut Control....................58
4.4 Fan Motor (DC Motor) or Related Abnormality.......................................59
4.5 Thermistor or Related Abnormality (Indoor Unit)....................................61
4.6 Refrigerant Shortage ..............................................................................62
4.7 Low-voltage Detection or Over-voltage Detection..................................64
4.8 Signal Transmission Error (between Indoor Unit and Outdoor Unit) ......66
4.9 Signal Transmission Error on Outdoor Unit PCB
(RX50/60G2V1B, 71 Class Only) ...........................................................68
4.10 Unspecified Voltage (between Indoor Unit and Outdoor Unit) ...............69
4.11 Outdoor Unit PCB Abnormality...............................................................70
4.12 OL Activation (Compressor Overload) ...................................................72
4.13 Compressor Lock ...................................................................................74
4.14 DC Fan Lock ..........................................................................................75
4.15 Input Overcurrent Detection ...................................................................76
4.16 Four Way Valve Abnormality..................................................................77
4.17 Discharge Pipe Temperature Control.....................................................79
4.18 High Pressure Control in Cooling ...........................................................80
4.19 Compressor System Sensor Abnormality ..............................................81
4.20 Position Sensor Abnormality ..................................................................83
4.21 CT or Related Abnormality (RX50/60G2V1B, 71 Class Only)................86
4.22 Thermistor or Related Abnormality (Outdoor Unit).................................88
4.23 Electrical Box Temperature Rise............................................................90
4.24 Radiation Fin Temperature Rise ............................................................91
4.25 Output Overcurrent Detection ................................................................93
5. Check ....................................................................................................95
5.1 Thermistor Resistance Check ................................................................95
5.2 Fan Motor Connector Output Check ......................................................96
5.3 Power Supply Waveforms Check...........................................................96
5.4 Electronic Expansion Valve Check.........................................................97
5.5 Four Way Valve Performance Check .....................................................98
5.6 Inverter Units Refrigerant System Check ...............................................98
5.7 Inverter Analyzer Check .........................................................................99
5.8 Rotation Pulse Check on the Outdoor Unit PCB ..................................100
5.9 Installation Condition Check.................................................................101
5.10 Discharge Pressure Check...................................................................101
5.11 Outdoor Fan System Check .................................................................102
5.12 Main Circuit Short Check......................................................................102
5.13 Capacitor Voltage Check......................................................................103
5.14 Power Module Check ...........................................................................103

Содержание

Скачать
Случайные обсуждения