Daikin 2MKS50GV1B [15/312] Holding functions no functions

Daikin 2MKS40G2V1B [15/312] Holding functions no functions
SiBE12-816_C Functions
List of Functions 4
Category Functions
FFQ25/35/50B8V1B
2MKS40/50GV1B
2MKS40/50G2V1B
Category Functions
FFQ25/35/50B8V1B
2MKS40/50GV1B
2MKS40/50G2V1B
Basic
Function
Inverter (with Inverter Power Control)
{{
Health &
Clean
Air-Purifying Filter
Operation Limit for Cooling (°CDB)
10
~46
Photocatalytic Deodorizing Filter
Operation Limit for Heating (°CWB)
Air-Purifying Filter with Photocatalytic
Deodorizing Function
——
PAM Control
{
Standby Electricity Saving
Titanium Apatite Photocatalytic
Air-Purifying Filter
——
Compressor Oval Scroll Compressor
Swing Compressor
{
Longlife Filter (Option)
{
Rotary Compressor Air Filter (Prefilter)
{
Reluctance DC Motor
{
Wipe-Clean Flat Panel
Comfortable
Airflow
Power-Airflow Flap Washable Grille
Power-Airflow Dual Flaps Filter Cleaning Indicator
{
Power-Airflow Diffuser MOLD PROOF Operation
Wide-Angle Louvers Good-Sleep Cooling Operation
Vertical Auto-Swing (Up and Down)
{
Timer WEEKLY TIMER Operation
Horizontal Auto-Swing (Right and Left) 72-Hour ON/OFF TIMER
{
3-D Airflow NIGHT SET Mode
COMFORT AIRFLOW Operation Worry Free
“Reliability &
Durability”
Auto-Restart (after Power Failure)
{
Comfort
Control
Auto Fan Speed Self-Diagnosis (Digital, LED) Display
{{
Indoor Unit Quiet Operation Wiring Error Check Function
NIGHT QUIET Mode (Automatic)
Anti-Corrosion Treatment of Outdoor
Heat Exchanger
{
OUTDOOR UNIT QUIET Operation
(Manual)
{
Flexibility Multi-Split / Split Type Compatible
Indoor Unit
{
2-Area INTELLIGENT EYE Operation H/P, C/O Compatible Indoor Unit
{
INTELLIGENT EYE Operation Flexible Voltage Correspondence
Quick Warming Function
(Preheating Operation)
High Ceiling Application
Hot-Start Function Chargeless 20 m
Automatic Defrosting Either Side Drain (Right or Left)
Operation Automatic Operation Power Selection
{
Program Dry Operation
{
Remote
Control
5-Rooms Centralized Controller (Option)
Fan Only
{
Remote Control Adaptor
(Normal Open Pulse Contact) (Option)
——
Lifestyle
Convenience
New POWERFUL Operation
(Non-Inverter)
——
Inverter POWERFUL Operation
Remote Control Adaptor
(Normal Open Contact) (Option)
——
Priority-Room Setting DIII-NET Compatible (Adaptor) (Option)
{
COOL / HEAT Mode Lock Remote
Controller
Wireless (Option)
{
HOME LEAVE Operation Wired
{
ECONO Operation
Indoor Unit ON/OFF Button
Signal Receiving Sign
R/C with Back Light
Temperature Display
Note:
{
: Holding Functions
: No Functions

Содержание