Daikin 2MKS50GV1B [5/312] Troubleshooting for outdoor unit 09

Daikin 2MKS50GV1B [5/312] Troubleshooting for outdoor unit 09
SiBE12-816_C
Table of Contents iv
2. Problem Symptoms and Measures .....................................................177
3. Service Check Function ......................................................................178
3.1 RA Indoor Unit - F(C)TXG, FTXS, FVXS, FLK(X)S,
FDK(X)S Series....................................................................................178
3.2 SA Indoor Unit - FFQ Series ................................................................187
4. Code Indication on Remote Controller ................................................192
4.1 RA Indoor Unit - F(C)TXG, FTXS, FVXS, FLK(X)S,
FDK(X)S Series....................................................................................192
4.2 SA Indoor Unit - FFQ Series ................................................................192
4.3 Outdoor Unit .........................................................................................193
5. Troubleshooting for RA Indoor Unit - F(C)TXG, FTXS, FVXS,
FLK(X)S, FDK(X)S Series...................................................................194
5.1 Indoor Unit PCB Abnormality ...............................................................194
5.2 Freeze-up Protection Control or Heating Peak-cut Control..................195
5.3 Fan Motor or Related Abnormality .......................................................197
5.4 Thermistor or Related Abnormality (Indoor Unit)..................................200
6. Troubleshooting for SA Indoor Unit - FFQ Series ...............................201
6.1 Indoor Unit PCB Abnormality ...............................................................201
6.2 Drain Water Level System Abnormality................................................202
6.3 Fan Motor or Related Abnormality .......................................................204
6.4 Drain System Abnormality....................................................................205
6.5 Thermistor or Related Abnormality.......................................................206
6.6 Remote Controller Air Thermistor Abnormality.....................................208
7. Troubleshooting for Outdoor Unit........................................................209
7.1 Anti-icing Control for Indoor Unit ..........................................................209
7.2 OL Activation (Compressor Overload) .................................................211
7.3 Compressor Lock .................................................................................212
7.4 DC Fan Lock ........................................................................................213
7.5 Input Overcurrent Detection .................................................................214
7.6 Discharge Pipe Temperature Control...................................................215
7.7 High Pressure Control in Cooling .........................................................216
7.8 Compressor Sensor System Abnormality ............................................217
7.9 Position Sensor Abnormality ................................................................218
7.10 DC Voltage / Current Sensor Abnormality............................................220
7.11 Thermistor or Related Abnormality (Outdoor Unit)...............................221
7.12 Electrical Box Temperature Rise..........................................................223
7.13 Radiation Fin Temperature Rise ..........................................................224
7.14 Output Overcurrent Detection ..............................................................226
7.15 Refrigerant Shortage ............................................................................228
7.16 Low-voltage Detection or Over-voltage Detection................................230
7.17 Outdoor Unit PCB Abnormality or Signal Transmission Error ..............231
7.18 Anti-icing control in Other Room / Unspecified Voltage
(between Indoor Unit and Outdoor Unit) ..............................................234
8. Check ..................................................................................................235
8.1 How to Check .......................................................................................235
Part 7 Removal Procedure ........................................................ 247
1. Outdoor Unit........................................................................................248
1.1 Removal of Outer Panels .....................................................................248
1.2 Removal of Electrical Box ....................................................................250
1.3 Removal of PCB...................................................................................255

Содержание

Скачать