Daikin RS60BVMB [81/170] Service check function

Daikin RS60BVMB [81/170] Service check function
Service Check Function Si06-305
72 Service Diagnosis
3. Service Check Function
3.1 ARC433 Series
In the ARC433A series, the temperature display sections on the main unit indicate
corresponding codes.
1. When the timer cancel button is held down for 5 seconds, a 00 indication flashes on the
temperature display section.
2. Press the timer cancel button repeatedly until a continuous beep is produced.
The code indication changes in the sequence shown below, and notifies with along beep.
Note: 1. A short beep and two consecutive beeps indicate non-corresponding codes.
2. To cancel the code display, hold the timer cancel button down for 5 seconds. The code
display also cancels itself if the button is not pressed for 1 minute.
No. Code No. Code No. Code
1 00 11 E7 21 UA
2 U4 12 C7 22 A5
3 F3 13 H8 23 J9
4 E6 14 J3 24 E8
5 L5 15 A3 25 P4
6 A6 16 A1 26 L3
7 E5 17 C4 27 L4
8 LC 18 C5 28 H6
9 C9 19 H9 29 H7
10 U0 20 J6 30 U2
(R2596)
<ARC433A5, A6>

Содержание

Скачать