Daikin FHC25JEVLK [28/32] Specifications

Daikin RYD40JEVLK [28/32] Specifications
1-26
NOTE:
This product is not designed for repacking. In case of re-packing, contact to Daikin Dealer.
MODEL INDOOR UNIT FHC30JEVLK FHC40JEVLK
OUTDOOR UNIT RD30JEVLK RD40JEVLK
RATED VOLTAGE V 220 220
RATED FREQUENCY Hz 60 60
COOLING (T1)
INDOOR
27DB
º
C/19WB
º
C
OUTDOOR
35DB
º
C/24WB
º
C
RATED CURRENT A 15.0 18.6
RATED POWER INPUT kW 3.11 4.01
CAPACITY Btu/h 28000 36000
kW 8.21 10.55
EER (Btu/h)/W 9.00 8.97
COOLING (T3)
INDOOR
29DB
º
C/19WB
º
C
OUTDOOR
46DB
º
C/24WB
º
C
RATED CURRENT A 16.9 21.1
RATED POWER INPUT kW 3.54 4.55
CAPACITY Btu/h 24800 32500
kW 7.27 9.53
EER (Btu/h)/W 7.00 7.14
NET WEIGHT INDOOR UNIT kg 31 39
OUTDOOR UNIT kg 61 81
REFRIGERANT R22 kg 1.75 2.20
COUNTRY OF ORIGIN INDOOR UNIT
Malaysia
OUTDOOR UNIT
Malaysia
MODEL INDOOR UNIT
FHYC30JEVLK FHYC40JEVLK
OUTDOOR UNIT RYD30JEVLK RYD40JEVLK
RATED VOLTAGE V 220 220
RATED FREQUENCY Hz 60 60
COOLING (T1)
INDOOR
27DB
º
C/19WB
º
C
OUTDOOR
35DB
º
C/24WB
º
C
RATED CURRENT A 15.0 18.6
RATED POWER INPUT kW 3.11 4.01
CAPACITY Btu/h 28000 36000
kW 8.21 10.55
EER (Btu/h)/W 9.00 8.97
COOLING (T3)
INDOOR
29DB
º
C/19WB
º
C
OUTDOOR
46DB
º
C/24WB
º
C
RATED CURRENT A 16.9 21.1
RATED POWER INPUT kW 3.54 4.55
CAPACITY Btu/h 24800 32500
kW 7.27 9.53
EER (Btu/h)/W 7.00 7.14
HEATING
INDOOR
20DB
º
C/--WB
º
C
OUTDOOR
7DB
º
C/6WB
º
C
RATED CURRENT A 12.8 17.2
RATED POWER INPUT kW 2.58 3.65
CAPACITY Btu/h 30000 38400
W 8.79 11.25
COP W/W 3.40 3.08
NET WEIGHT INDOOR UNIT kg 31 39
OUTDOOR UNIT kg 61 81
REFRIGERANT R22 kg 1.75 2.20
COUNTRY OF ORIGIN INDOOR UNIT
Malaysia
OUTDOOR UNIT
Malaysia
SPECIFICATIONS
EN CKE-0911(0)DK(saso).indd 26 12/6/11 3:05:13 PM