Haier AC122ACERA [260/408] Electrical wiring diagram and pcb photo

Haier AU60NAIEAA [260/408] Electrical wiring diagram and pcb photo
Time shorting
switch CN7
Emergency switch
SW1(receiver)
BM1(1) BM1(2)
Time shorting switch Time shorting * * *
Emergency switch * Emergency * *
No outdoor PCB * *
hh
Jumper selection (Ĝshows jumper connected, ON; hshows jumper disconnected, OFF; * shows
no limitation)
With outdoor PCB, fixed
speed single split unit
* *
Ĝh
With outdoor PCB, fixed
speed multi split unit
* *
With outdoor PCB,
inverter single split unit
* *
ĜĜ
Inverter unit selection BM2(1) BM2(2) BM2(3) BM2(4)
Temp. compensation 4
ć available/not
available
Ĝ/h
* * *
Wired control/ infrared
control
*
Ĝ/h
* *
Cooling only/heatpump * *
Ĝ/h
*
Master/slave wired
controller
* * *
Ĝ/h
BM4 BM3
address 1 2 3 4 1 2 3 4
1
h h h h h h h hshows
2
Ĝ h h h h h h
3
h Ĝ h h h h h
4
Ĝ Ĝ h h h h h
no
network
home
appliance
5
h h Ĝ h h h h
6
Ĝ h Ĝ h h h h
ĂĂ ĂĂ ĂĂ ĂĂ ĂĂ ĂĂ ĂĂ
126
Ĝ h Ĝ Ĝ Ĝ Ĝ Ĝ
127
h Ĝ Ĝ Ĝ Ĝ Ĝ Ĝ
128
Ĝ Ĝ Ĝ Ĝ Ĝ Ĝ Ĝ
Ĝwith
network
home
appliance
Network address selection (Ĝshows jumper connected, ON; hshows jumper disconnected, OFF)
0010452325E / 0010452478E information - function selection
Electrical wiring diagram and PCB photo
-243-

Содержание