Haier 1U12EH1ERA [19/109] Urgent on off input

Содержание

Haier Funcitions control hours and then close down 2 3 During the dormant time except the change of the system mode or a new press on the dormant setting keys the timing of the 8 hours dormancy will take the first timing as the start time any presses on other keys will not affect the original timing 2 4 Indoor fan control under the dormant operation If the indoor fan is at the high speed before the dormant operation setting the speed will be turned to medium after the setting If the fan is at the medium speed before the dormant setting the speed will be turned to low after the setting If the fan is at the low speed before the dormant setting the speed will not change 5 1 10 Urgent on off input Press the urgency button the buzzer will ring The system will enter the automatic mode if you don t press the button for more than 5 seconds Under the system off mode if you press the urgency key for 5 to 10 seconds the system will start the test operation Under the system off mode if you press the urgency key for 10 to 15 seconds the display screen will show the resume of the last malfunction If the system is under operation the press on the urgency key will stop it Under the system off mode the display screen will show automatic running sign Under the system off mode the system will not receive the remote control signal if the press on the urgency key doesn t last for 15 seconds or if the key is loosened Urgency operation If you press the urgency key for less than 5 seconds the buzzer will ring when you press the on off key The system will enter the urgency operation when the urgency key is loosened The urgency operation is fully automatic Test operation The inlet temperature sensor doesn t work the indoor fan and the indoor air direction board motor works synchronically High speed airflow cooling outdoor system on etc will send the ambient temperature 30 centigrade and coil temperature 16 centigrade information to the outdoor system Test operation The defrost protection of the evaporator doesn t work The temperature control doesn t work The test operation will be finished in 30 minutes The test operation can be stopped by the relative commands from the remote control 5 1 11 Low load protection control In order to prevent the frosting of the indoor heat interaction device the outdoor system will be stopped if the indoor heat interaction temperature is below zero centigrade for 5 minutes but the fan will continue to operate The outdoor system will be started again when the heat interaction temperature is above 7 centigrade and the system has been stopped for 3 minutes The malfunction will be stored in the malfunction resume and will not be revealed 5 1 12 High load protection control The outdoor system will be stopped if the coil temperature is above 65 C for 2 minutes The indoor fan will be controlled by the thermostat The outdoor system can be restarted when the coil temperature is below 42 C and the system has been stopped for 3 minutes The malfunction will be stored in the malfunction resume and will not be revealed 5 1 13 Abnormal operation of indoor system When the outdoor system operates if the indoor system operation differs from the outdoor system the abnormal operation malfunction will be reported 10s after the report the indoor system will be closed Outdoor system mode Indoor system mode conflicts cooling heating yes cooling cooling no cooling airflow no heating heating no heating airflow yes heating cooling yes Haier 16 Domestic Air Conditioner

Скачать