Hotpoint-Ariston HKQV 9 K [16/40] English
![Hotpoint-Ariston HKQV 9 K [16/40] English](/views2/1954480/page16/bg10.png)
English
16
EN
The hood can look different to that illustrated in the drawings in this
booklet. The instructions for use, maintenance and installation, however,
remain the same.
! It is important to conserve this booklet for consultation at any moment. In
the case of sale, cession or move, make sure it is together with the product.
! Read the instructions carefully: there is important information about
installation, use and safety.
! Do not carry out electrical or mechanical variations on the product or on the
discharge conduits.
GENERAL SAFETY
The minimum distance between the supporting surface for the cooking
equipment on the hob and the lowest part of the range hood must be not less
than 40cm from electric cookers and 65cm from gas or mixed cookers.
If the instructions for installation for the gas hob specify a greater distance, this
must be adhered to.
Expansion wall plugs are provided to secure the hood to most types of
walls/ceilings. However, a qualified technician must verify suitability of the
materials in accordance with the type of wall/ceiling. The wall/ceiling must be
strong enough to take the weight of the hood. Do not tile, grout or silicone this
appliance to the wall. Surface mounting only.
WARNING! Do not connect the appliance to the mains until the installation is
fully complete.
Before any cleaning or maintenance operation, disconnect hood from the mains
by removing the plug or disconnecting the mains electrical supply.
Always wear work gloves for all installation and maintenance operations.
The appliance is not intended for use by children or persons with impaired
physical, sensorial or mental faculties, or if lacking in experience or knowledge,
unless they are under supervision or have been trained in the use of the
appliance by a person responsible for their safety.
This appliance is designed to be operated by adults, children should be
monitored to ensure that they do not play with the appliance.
This appliance is designed to be operated by adults. Children should not be
allowed to tamper with the controls or play with the appliance.
Never use the hood without effectively mounted grating!
The hood must NEVER be used as a support surface unless specifically
indicated.
The premises where the appliance is installed must be sufficiently ventilated,
when the kitchen hood is used together with other gas combustion devices or
other fuels.
The ducting system for this appliance must not be connected to any existing
ventilation system which is being used for any other purpose such as discharging
exhaust fumes from appliances burning gas or other fuels.
The flaming of foods beneath the hood itself is severely prohibited.
The use of exposed flames is detrimental to the filters and may cause a fire risk,
and must therefore be avoided in all circumstances.
Any frying must be done with care in order to make sure that the oil does not
overheat and ignite.
Accessible parts of the hood may became hot when used with cooking
applicance.
With regards to the technical and safety measures to be adopted for fume
discharging it is important to closely follow the regulations provided by the local
authorities.
The hood must be regularly cleaned on both the inside and outside (AT LEAST
ONCE A MONTH).
This must be completed in accordance with the maintenance instructions
provided in this manual). Failure to follow the instructions provided in this user
guide regarding the cleaning of the hood and filters will lead to the risk of fires.
Do not use or leave the hood without the lamp correctly mounted due to the
possible risk of electric shocks.
We will not accept any responsibility for any faults, damage or fires caused to the
appliance as a result of the non-observance of the instructions included in this
manual.
ELECTRICAL CONNECTION
The mains power supply must correspond to the rating indicated on the plate
situated inside the hood. If provided with a plug connect the hood to a socket in
compliance with current regulations and positioned in an accessible area, after
installation. If it not fitted with a plug (direct mains connection) or if the plug is not
located in an accessible area, after installation, apply a double pole switch in
accordance with standards which assures the complete disconnection of the
mains under conditions relating to over-current category III, in accordance with
installation instructions.
Warning! Before re-connecting the hood circuit to the mains supply and
checking the efficient function, always check that the mains cable is correctly
assembled.
Replacing the power cable
Warning! Power cable replacement must be undertaken by the authorised
service assistance centre or similar qualified person.
AIR VENT
(for the suction versions)
Connect the hood and discharge holes on the walls with a diameter equivalent to
the air outlet (connection flange).
Using the tubes and discharge holes on walls with smaller dimensions will cause
a diminution of the suction performance and a drastic increase in noise.
Any responsibility in the matter is therefore declined.
! Use a duct of the minimum indispensible length.
! Use a duct with as few elbows as possible (maximum elbow angle: 90°).
! Avoid drastic changes in the duct cross-section.
! Use a duct with an as smooth as possible inside.
! The duct must be made of certified material.
! The company declines any responsibility whenever these regulations are
not respected.
FILTERING OR DUCTING ?
! Your hood is ready for use in the filtering version and can be installed in the
external exhausting version by removing the carbon filter and installing a
discharge tube (to be purchased) to connect the tube to the exterior.
! The telescopic chimney is available as an extra accessory kit.
The information for the installation of the telescopic chimney is already contained
in this manual.
Ducting version
In this case the fumes are conveyed outside of the building by means of a
special pipe connected with the connection ring located on top of the hood.
Attention! The exhausting pipe is not supplied and must be purchased apart.
Diameter of the exhausting pipe must be equal to that of the connection ring.
In the horizontal runs the exhausting pipe must be slightly slanted (about 10°)
and directed upwards to vent the air easily from the room to the outside.
Attention! If the hood is supplied with active charcoal filter, then it must be
removed.
Filter version
One active charcoal filter is needed for this and can be obtained from your usual
retailer.
The filter removes the grease and smells from the extracted air before sending it
back into the room through the upper outlet grid.
Содержание
- Istruzioni per l uso betriebsanleitung instructions for use mode d emploi gebruiksaanwijzingen instrucciones de uso instruções de uso инструкция по зксплуатации 1
- Collegamento elettrico 8
- Filtrante o aspirante 8
- Italiano 8
- Scarico dell aria 8
- Sicurezza generale 8
- Comandi 9
- Manutenzione 10
- Smaltimento 10
- Anomalie di funzionamento 11
- Dati tecnici 11
- Ableitung der abluft 12
- Allgemeine sicherheit 12
- Deutsch 12
- Elektrischer anschluss 12
- Umluft oder abluftbetrieb 12
- Bedienelemente 13
- Wartung 13
- Entsorgung 14
- Betriebsstörungen 15
- Technische daten 15
- Air vent 16
- Electrical connection 16
- English 16
- Filtering or ducting 16
- General safety 16
- Controls 17
- Maintenance 17
- Disposal 18
- Malfunctions 19
- Technical data 19
- Branchement électrique 20
- Filtrante ou aspirante 20
- Français 20
- Sécurité générale 20
- Évacuation de l air 20
- Commandes 21
- Entretien 21
- Élimination 22
- Anomalies de fonctionnement 23
- Données technique 23
- Algemene veiligheid 24
- Elektrische aansluiting 24
- Filterend of afzuigend apparaat 24
- Luchtafvoer 24
- Nederlands 24
- Bedieningselementen 25
- Onderhoud 25
- Verwijdering 26
- Storingen 27
- Technische gegevens 27
- Conexión eléctrica 28
- Español 28
- Extracción de aire 28
- Filtrante o aspirante 28
- Seguridad general 28
- Mandos 29
- Mantenimiento 29
- Eliminación 30
- Anomalías de funcionamiento 31
- Datos técnicos 31
- Conexão elétrica 32
- Filtrante ou aspirante 32
- Português 32
- Saída do ar 32
- Segurança geral 32
- Comandos 33
- Manutenção 33
- Eliminação 34
- Anomalias de funcionamento 35
- Dados técnicos 35
- Выброс воздуха 36
- Общие правила техники безопасности 36
- Русский 36
- С рециркуляцией или с выводом 36
- Электрическое соединение 36
- Команды 37
- Техническое обслуживание 37
- Утилизация 38
- Аномалии в работе 39
- Технические данные 39
Похожие устройства
- Hotpoint-Ariston HL 61 IX Руководство по эксплуатации
- Kuppersberg ANABEL Инструкция по эксплуатации
- Kuppersberg BONA Инструкция по эксплуатации
- Kuppersberg DDA Инструкция по эксплуатации
- Kuppersberg DOMINIKA Инструкция по эксплуатации
- Kuppersberg F 600 Руководство по эксплуатации
- Kuppersberg F 625 Руководство по эксплуатации
- Kuppersberg F 626 Руководство по эксплуатации
- Kuppersberg F 925 Руководство по эксплуатации
- Kuppersberg F 926 Руководство по эксплуатации
- Kuppersberg FEODORA Инструкция по эксплуатации
- Kuppersberg FW 610 Руководство по эксплуатации
- Kuppersberg FW 620 Руководство по эксплуатации
- Kuppersberg FW 910 Руководство по эксплуатации
- Kuppersberg INLINEA Инструкция по эксплуатации
- Kuppersberg KAMINOX 60 Руководство по эксплуатации
- Kuppersberg KAMINOX 90 Руководство по эксплуатации
- Kuppersberg KATRIN Инструкция по эксплуатации
- Kuppersberg LORA 60 Руководство по эксплуатации
- Kuppersberg LORA 90 Руководство по эксплуатации