CC2000 User Manual
198
5. Use the drop-down menu Version to select from one of the three options
available, SNMPv21, SNMPv2c, and SNMPv3.
6. Key in the Community/Username value(s) for the SNMP version and
select Security level.
7. Use the drop-down menu Authentication to select your authentication
type, and key in the authentication password(s) in Authentication
password field that correspond to each of the stations.
8. Use the drop-down menu Privacy to select your Privacy type and key in
the privacy password(s) in Privacy password field that correspond to
each of the stations.
9. Repeat steps 4–8 for up to three further SNMP managers.
10. When all your settings have been made, click Save.
Note: Make sure all the fields are filled in correctly so the system can
successfully save your settings.
Syslog
To record all the events that take place on the CC2000 and write them to a
Syslog server, do the following:
1. Check the Enable Syslog service checkbox.
2. Key in the IP address in the Server IP/Domain field and the port number
of the Syslog server in Port field. The valid port range is 1-65535.