SNR S2989G-48TX-DC — управление коммутатором через SNMP и CLI интерфейс [25/553]

Превью страниц Страница 25 / 553
SNR S2989G-24TX [25/553] Software
S2989G-24TX Operation Manual
Chapter
1
Basic
Management
Configuration
1-10
1.1.1.2.3 Manage the Switch via SNMP Network Management
Software
The necessities required by SNMP network management software to manage switches:
1) IP addresses are configured on the switch;
2) The IP address of the client host and that of the VLAN interface on the switch it
subordinates to should be in the same segment;
3) If 2) is not met, the client should be able to reach an IP address of the switch
through devices like routers;
4) SNMP should be enabled.
The host with SNMP network management software should be able to ping the IP
address of the switch, so that, when running, SNMP network management software will
be able to find it and implement read/write operation on it. Details about how to manage
switches via SNMP network management software will not be covered in this manual,
please refer to Snmp network management software user manual”.
1.1.2
CLI Interface
The switch provides thress management interface for users: CLI (Command Line