SNR S2989G-48TX-DC — настройка IP-адресов для сетевых коммутаторов и VLAN [37/553]

Превью страниц Страница 37 / 553
SNR S2989G-48TX-DC [37/553] Switch ip addresses configuration task list
S2989G-24TX Operation Manual
Chapter
1
Basic
Management
Configuration
1-22
Switch(config)#interface vlan 1
Switch(Config-if-Vlan1)#ip address 100.100.100.200 255.255.255.0
Switch(Config-if-Vlan1)#exit
Switch(config)#username test privilege 15 password 0 test
In IPv6 networks, the terminal should run SSH client software which support IPv6,
such as putty6. Users should not modify the configuration of the switch except allocating
an IPv6 address for the local host.
1.2.3
Configure Switch IP Addresses
All Ethernet ports of switch are default to Data Link layer ports and perform layer 2
forwarding. VLAN interface represent a Layer 3 interface function which can be assigned
an IP address, which is also the IP address of the switch. All VLAN interface related
configuration commands can be configured under VLAN Mode. Switch provides three IP
address configuration methods:
Manual
BOOTP
DHCP
Manual configuration of IP address is assign an IP address manually for the switch.
In BOOTP/DHCP mode, the switch operates as a BOOTP/DHCP client, send
broadcast packets of BOOTPRequest to the BOOTP/DHCP servers, and the
BOOTP/DHCP servers assign the address on receiving the request. In addition, switch
can act as a DHCP server, and dynamically assign network parameters such as IP
addresses, gateway addresses and DNS server addresses to DHCP clients DHCP Server
configuration is detailed in later chapters.
1.2.3.1 Switch IP Addresses Configuration Task List
1. Enable VLAN port mode
2. Manual configuration
3. BOOTP configuration
4. DHCP configuration
1. Enable VLAN port mode
Explanation
Create VLAN interface (layer 3 interface);
the no command deletes the VLAN
interface.

Содержание