Gorenje GTW6INI [8/52] Adaptation to a different type of gas

Gorenje GTW6INI [8/52] Adaptation to a different type of gas
8
TECHNICAL INFORMATION
493044
493045
A: Auxiliary
SR: Semirapid
MW: Mini-Wok
Operating voltage
220-240 V~ ; 50/60 Hz
Regulated for gas G20 = 20mbar
Qn
GAS HOB
7,8 kW
NOZZLE TABLE
Burner A SR MW
Rated heat output (kW) 1,00 1,75 3,30
Reduced Rate (kW) 0,45 0,70 1,50
Ø INJECTOR (mm)
G30 30mbar 0,50 0,65 0,90
G20 20mbar 0,72 - X 0,97 - Z 1,28 - T
G20 13mbar 0,84 1,10 1,48
Ø BY-PASS (mm)
G30 30mbar 0,27 0,31 0,55
G20 20mbar REG. REG. REG.
G20 13mbar REG. REG. REG.
ADAPTATION TO A DIFFERENT TYPE OF GAS
COUNTRY OF DESTINATION GAS AND SUPPLY PRESSURE
KZ G30=30mbar ; G20=20mbar ; G20=13mbar
MD G30=30mbar ; G20=20mbar ; G20=13mbar
RU G30=30mbar ; G20=20mbar ; G20=13mbar
UA G30=30mbar ; G20=20mbar ; G20=13mbar
Important warnings
• The gas burners are fitted a candle as flame failure device. If the burner flame is
extinguished accidentally or unintentionally (e.g. when some liquid boils over or
when there is draught in the room):
gas supply is automatically cut off, thus preventing the gas from being
emitted into the room.
• Gas burner cover should always be placed on the burner crown very carefully. Make
sure the slots on the burner crown are never obstructed.
1 Burner crown cover
2 Burner crown with the support for the burner cover
3 Candle flame failure device
4 Ignition candle
5 Nozzle
Wok cradle
The auxiliary support supplied for the wok burner or available as an accessory provides
additional stability in case of a wok with a round base. The auxiliary support for the wok
has special recesses so it can be positioned neatly on top of the standard wok pan
support.