Adaptec asr-5405 kit [69/116] Failed ssd in maxcache device

Adaptec asr-5405 kit [69/116] Failed ssd in maxcache device
For more information, refer to the Adaptec RAID Controller Command Line Interface Users Guide and
the maxView Storage Manager User's Guide.
Note: In some instances, RAID 10 and RAID 50 arrays may survive multiple disk drive
failures, depending on which disk drives fail.
Failed SSD in maxCache Device
Because the maxCache Device is a redundant logical device, comprised of SSDs only, it is rebuilt
automatically when a failed SSD is replaced, just like an ordinary array. Once you identify the failed SSD,
for example, by using maxView Storage Manager's rapid fault isolation feature, replace it with a new
one (see Connecting Solid State Drives (SSDs) on page 45). The controller detects the new SSD and
begins rebuilding the maxCache Device.
Resetting the Controller
You may need to reset, or ash, your Adaptec RAID controller if it becomes inoperable or if a rmware
upgrade is unsuccessful. Adaptec RAID controllers support a reset protocol called HDA mode ash. For
information about HDA mode, see the Readme or contact your support representative. To locate the
ash jumper on your RAID controller board, see the illustrations in About Your RAID Controller on page
16.
69Proprietary and Condential to PMC-Sierra, Inc., and for its customers.
Document No.: CDP-00310-01-A Rev. A, Issue
Serial Attached SCSI RAID Controllers Installation and User's Guide

Содержание

Скачать