Zyxel IES-6000 [1040/1156] 5 sys timeserver sync command

Zyxel IES-5106 [1040/1156] 5 sys timeserver sync command
Chapter 36 sys Commands
Management Switch Card User’s Guide
1040
This command sets the system to use a time server.
The following example sets the system to use NTP protocol to access a time server at IP address
140.112.2.189 and sets the system’s time zone to eight hours ahead of UTC. It also has the system
synchronize the time with the time server.
36.3.15 sys timeserver sync Command
Syntax:
sys timeserver sync
This command has the system get the time and date from the time server. An example is shown
next.
36.3.16 sys info chassis Command
Syntax:
sys info chassis <chassis>
where
This command sets the system chassis number.
daytime =
The Daytime time service protocol (RFC 867). When you select this format, the
switch displays the day, month, year and time with no time zone adjustment.
When you use this format it is recommended that you use a Daytime
timeserver within your geographical time zone.
time|ntp =
The time service protocol.
time: Time (RFC 868) format displays a 4-byte integer giving the total
number of seconds since 1970/1/1 at 0:0:0.
ntp: NTP Network Time Protocol (RFC 1305) is similar to Time (RFC 868).
<ip-address> =
The IP address of the time server.
<utc[<+|->
0100~1200]>
=
The time difference between UTC (Universal Time Coordinated, formerly known
as GMT, Greenwich Mean Time) and your time zone.
[sync] =
This sets the system to synchronize with the time server.
ras> sys timeserver set ntp 140.112.2.189 utc +0800 sync
sync with time server...success
ras>
ras> sys timeserver sync
sync with time server...success
ras>
<chassis>
=
The chassis number (an integer from 1 to 64). The chassis number
helps to keep track of this individual unit in a multiple unit
application.