Zyxel IES-6000 [371/1156] Alarm vdsl2 channel profile setup

Zyxel IES-5106 [371/1156] Alarm vdsl2 channel profile setup
Chapter 12 Profile Screens
Management Switch Card User’s Guide
371
12.16.2 Alarm VDSL2 Channel Profile Setup
Click the ChanProfile link at the top-right corner of the Alarm VDSL2 screen to display the screen
as shown. Use this screen to view, add, edit, modify a VDSL channel alarm profile.
The device sends an alarm trap and generates a syslog entry when the thresholds of the alarm
profile are exceeded.
XTUC Configure the thresholds in this column for the system (XTUC).
XTUR Configure the thresholds in this column for CPE devices (XTUR).
15 Minute FECS
Threshold
Enter the number of Forward Error Correction Seconds (FECS) that are permitted to occur
within 15 minutes.
15 Minute ES
Threshold
Enter the number of Errored Seconds (ES) that are permitted to occur within 15 minutes.
15 Minute SES
Threshold
Enter the number of Severely Errored Seconds (SES) that are permitted to occur within
15 minutes.
15 Minute LOSS
Threshold
Enter the number of Loss Of Signals Seconds (LOSS) that are permitted to occur within
15 minutes.
15 Minute UAS
Threshold
Enter the number of UnAvailable Seconds (UAS) that are permitted to occur within 15
minutes.
15 Minute LOFS
Threshold
Enter the number of Loss Of Framing Seconds (LOFS) that are permitted to occur within
15 minutes.
15 Minute LPRS
Threshold
Enter the number of times a Loss of PoweR Seconds (LPRS) is permitted to occur within
15 minutes.
15 Minute LOLS
Threshold
Enter the number of times a Loss of Link Second (LOLS) is permitted to occur within 15
minutes.
Apply Click Apply to save the changes in this screen to the system’s volatile memory. The
system loses these changes if it is turned off or loses power, so use the Config Save link
on the navigation panel and then the Save button to save your changes to the non-
volatile memory when you are done configuring.
New While you are modifying a profile, you can click New to start configuring a fresh profile
without saving your changes.
Cancel Click Cancel to start configuring the screen again.
Index This is the index number of the alarm profile.
Name This field displays the descriptive name for the alarm profile.
Modify Select a profile’s Select radio button and click Modify to edit the profile.
Delete Select a profile’s Select radio button and click Delete to remove the profile.
Table 177 Profile > Alarm VDSL2 > LineProfile (continued)
LABEL DESCRIPTION