Zyxel IES-6000 [876/1156] Profile alarmshdsl set command

Zyxel IES-5106 [876/1156] Profile alarmshdsl set command
Chapter 32 profile Commands
Management Switch Card User’s Guide
876
This command displays the details of the specified alarm SHDSL profile or lists all of the alarm
SHDSL profiles if you do not specify one.
The following example displays the default alarm SHDSL profile (DEFVAL).
32.8.2 profile alarmshdsl set Command
Syntax:
<profile> [atten <atten>] [snrmgn <snrmgn>] [es <es>] [ses <ses>][crc <crc>] [losws
<losws>] [uas <uas>]
where
This command configures SHDSL port alarm thresholds. The system sends an alarm trap and
generates a syslog entry when the thresholds of the alarm profile are exceeded.
Configure
alarmshdsl profiles first and then use the port shdsl alarmprof command to to
use them with specific SHDSL ports.
The following example sets an alarm profile named SESalarm that has the system send an alarm
trap and generate a syslog whenever the connection’s number of severely errored seconds exceeds
three within a 15 minute period.
ras> profile alarmshdsl show DEFVAL
shdsl alarm profile : DEFVAL
loop attenuation(atten) (dB): 0
snr margin(snrmgn) (dB): 0
es (sec): 0
ses (sec): 0
crc anomalies(crc) : 0
losws (sec): 0
uas (sec): 0
ras>
<profile>
=
A name for the alarm profile (up to 31 English keyboard characters).
<atten>
=
The permitted loop attenuation of a port, 0~127
<snrmgn>
=
The permitted signal to noise ratio margin, 0~15.
<ess>
=
The number of Errored SecondS (0~900) that are permitted to occur within 15
minutes.
<ses>
=
The number of Severely Errored Seconds (0~900) that are permitted to occur within
15 minutes.
<crc>
=
The number of Cyclic Redundancy Checking anomalies that are permitted to occur
within 15 minutes.
<losws>
=
The number of Loss Of Sync Word Seconds (0~900) that are permitted to occur
within 15 minutes.
<uas>
=
The number of UnAvailable Seconds (0~900) that are permitted to occur within 15
minutes.
ras> profile alarmshdsl set SESalarm ses 3