Zyxel IES-6000 [367/1156] Alarm vdsl profile screen

Zyxel IES-5112 [367/1156] Alarm vdsl profile screen
Chapter 12 Profile Screens
Management Switch Card User’s Guide
367
12.15 Alarm VDSL Profile Screen
Click Profile> Alarm VDSL in the navigation panel to open the following screen. Use this screen to
configure alarm profiles for the VDSL ports. Later you can apply the alarm VDSL profiles to VDSL
ports in the VDSL Port Setup screens.
Alarm VDSL profiles define VDSL port alarm thresholds. The system sends an alarm trap and
generates a syslog entry when the thresholds of the alarm profile are exceeded.
15 Min SESL
[0~900]
This field sets the limit for the number of Severely Errored Seconds that are permitted to
occur within 15 minutes.
15 Min UASL
[0~900]
This field sets the limit for the number of UnAvailable Seconds that are permitted to occur
within 15 minutes.
15 Min Failed
Fast [0~900]
This field sets the limit for the number of failed fast retrain seconds that are permitted to
occur within 15 minutes.
Init Failure Trap Select Enable to trigger an alarm for an initialization failure trap.
Fast Rate Up
[0~2147483]
(kbps)
Specify a rate in kilobits per second (kbps). If a fast mode connection’s upstream
transmission rate increases by more than this number, then a trap is sent.
Fast Rate Down
[0~2147483]
(kbps)
Specify a rate in kilobits per second (kbps). If a fast mode connection’s downstream
transmission rate decreases by more than this number, then a trap is sent.
Interleave Rate
Up [0~2147483]
(kbps)
Specify a rate in kilobits per second (kbps). If an interleave mode connection’s upstream
transmission rate increases by more than this number, then a trap is sent.
Interleave Rate
Down
[0~2147483]
(kbps)
Specify a rate in kilobits per second (kbps). If an interleave mode connection’s upstream
transmission rate decreases by more than this number, then a trap is sent.
Apply Click Apply to save the changes in this screen to the system’s volatile memory. The
system loses these changes if it is turned off or loses power, so use the Config Save link
on the navigation panel and then the Save button to save your changes to the non-
volatile memory when you are done configuring.
New While you are modifying a profile, you can click New to start configuring a fresh profile
without saving your changes.
Cancel Click Cancel to start configuring the screen again.
The bottom part of the screen lists the configured profiles.
Index This is the index number of the alarm profile.
Name This is the name of the alarm profile.
Modify Select a profile’s Select radio button and click Modify to edit the profile.
Delete Select a profile’s Select radio button and click Delete to remove the profile.
Table 174 Alarm ADSL Profile (continued)
LABEL DESCRIPTION