Zyxel IES-6000 [156/1156] Alarm severity msc alc slc vlc vop ima description

Zyxel IES-5112 [156/1156] Alarm severity msc alc slc vlc vop ima description
Chapter 5 Alarm Screens
Management Switch Card User’s Guide
156
ANTI_SPOOFING Minor X A system connected to the MSC detected
a MAC address connected to more than
one port.
CLUSTER_MBR_ACTIVE INFO X The cluster manager has established a
connection with a particular cluster
member.
CLUSTER_MBR_INACTIVE INFO X The cluster manager has established a
connection with a particular cluster
member.
CLUSTER_MBR_ADD INFO X The cluster manager added a member to
a cluster.
CLUSTER_MBR_DELETE INFO X The cluster manager removed a member
from cluster.
PING_PROBE_FAIL INFO X A continuous ping test via diagnostic tool
is failed.
PING_TEST_FAIL INFO X A ping test via diagnostic tool is failed.
PING_TEST_COMPLETE INFO X A ping test via diagnostic tool is
completed.
TRACERT_TEST_FAIL INFO X A trace route test via diagnostic tool is
failed.
TRACERT_TEST_COMPLET
E
INFO X A trace route test via diagnostic tool is
completed.
Ethernet
ENET_UP INFO X An MSC Gigabit Ethernet interfaces is
up.
ENET_DOWN MINOR X An MSC Gigabit Ethernet interfaces is
down.
ENET_LOOPGUARD MINOR X A network loop has been detected.
ENET_SFP_ERROR MAJOR An MSC SFP transceiver has errors.
ENET_SFP_TX_ENABLE INFO A fiber optic transmission on the MSC is
enabled.
ENET_SFP_TX_DISABLE INFO A fiber optic transmission on the MSC is
disabled.
VoIP
VOP_TEMP_ERROR CRITICAL X A SLAC thermal fault has been detected
on a VOP card’s.
VOP_DC_POWER_FAIL CRITICAL X A SLAC DC fault has been detected on a
VOP card’s telephone line.
VOP_AC_POWER_FAIL CRITICAL X A SLAC AC fault has been detected on a
VOP card’s telephone line.
VOP_RING_TIMER_FAIL CRITICAL X A VOP card’s ring timer failed.
VOP_RING_RSRCE_FAIL CRITICAL X Too many ports are ringing, so there was
not enough ring power to ring the phone
connected to this port.
VOP_RING_OHD_FAIL INFO X A ring overload indication has been
detected. A VOP card is close to using its
full ring power and will reduce the ring
output power if the load continues to
increase.
Table 60 Alarm Descriptions (continued)
ALARM SEVERITY MSC ALC SLC VLC VOP IMA DESCRIPTION