Zyxel IES-6000 [167/1156] Cfm overview

Zyxel IES-5106 [167/1156] Cfm overview
Management Switch Card User’s Guide 167
CHAPTER 7
Diagnostic Screens
This chapter explains the Diagnostic screens.
7.1 CFM Overview
The route between a CO network and one of a CPE user may go through aggregated switches,
routers and/or DSLAMs owned by independent organizations. A connectivity fault point generally
takes time to discover and impacts on subscribers’ network access. In order to reduce management
and maintenance requirements, the IEEE 802.1ag Connectivity Fault Management (CFM)
specification was developed to allow network administrators to identify and manage connection
faults. Through discovery and verification of packet paths, CFM can detect and analyze connectivity
faults in bridged LANs.
The figure shown below is an example of a connection fault between switches on the LAN. CFM can
be used to identify and manage this kind of connection problem.
Figure 89 Management for any Fault in Bridges
7.1.1 How CFM Works
To enable CFM, a pro-active Connectivity Check (CC) between two CFM-aware devices in the same
MD (Maintenance Domain) network takes place. An MA (Maintenance Association) defines a VLAN
and associated ports on the device under an MD level. In this MA, a port can be an MEP
(Maintenance End Point) port or an MIP (Maintenance Intermediate Point) port.
MEP port - has the ability to send pro-active connectivity check (CC) packets and get other MEP
ports information from the CC packets of neighboring switches within an MA.
MIP port - only forwards the CC packets.
CPE
CO
Internet