Zyxel IES-6000 [151/1156] Chapter 5 alarm screens

Zyxel IES-5112 [151/1156] Chapter 5 alarm screens
Chapter 5 Alarm Screens
Management Switch Card User’s Guide
151
Figure 82 Alarm EditSeverity Assignment: DSL
The following table describes the labels in this screen.
Table 59 Alarm EditSeverity Assignment
LABEL DESCRIPTION
Condition This identifies an individual alarm. See Section 5.5 on page 152 for all individual alarm
information.
Facility Select the log facility (local1~local7) to have the device log the syslog messages to a
specific file in the syslog server. See your syslog program’s documentation for details.
SNMP Select the check box to have the switch send SNMP traps of the specified alarm condition.
Syslog Select the check box to have the switch send syslog messages of the specified alarm
condition.
Severity Select the severity level from info, minor, major and critical for the specified alarm
condition.
Clearable Select the check box to allow an administrator to manually remove records of the specified
alarm.
Select All Select an option from the Select All drop-down list box to automatically select that option
for all entries. Alternatively, you may configure individual entries.
Select a Select All check box to automatically select that option for all entries. Clear it to
clear that option for all entries. Alternatively, you may select or clear the check boxes for
individual entries.
Apply Click Apply to save the changes in this screen to the system’s volatile memory. The system
loses these changes if it is turned off or loses power, so use the Config Save link on the
navigation panel and then the Save button to save your changes to the non-volatile
memory when you are done configuring.
Cancel Click Cancel to begin configuring the screen again.