21.3.10 alarm xedit Command
Syntax:
alarm xedit <alarm> <cond> <severity> <fac> <target>[,<target>] <clearable>
where
This command sets the severity level of an alarm(s) and where the system is to send the alarm(s).
You can also set whether or not the alarm can be manually cleared from the system.
Use the
alarm tablelist command to display alarm setting details.
The following example creates an alarm report entry that sets all system alarms to the major
severity level and sends them to a syslog server at the local 3 log facility. It also sets the system
alarms to be manually clearable.
ras> alarm tablelist
no alarm (code)condition facility snmp syslog severity
clearable
--- ------ ------------------------- --------- ---- ------ -------- -------
1 dsl ( 5002)LINE_UP local1 V V info -
2 dsl ( 5003)LINE_DOWN local1 V V minor V
3 dsl ( 5006)LINE_LDM_START local1 V V info -
4 dsl ( 5007)LINE_LDM_END local1 V V info -
-------------------------- [snip] --------------------------
17 dsl ( 5024)SHDSL_TCA_SNRM local1 V V info V
18 dsl ( 5025)SHDSL_TCA_ES local1 V V info V
19 dsl ( 5026)SHDSL_TCA_SES local1 V V info V
Press any key to continue, 'e' to exit, 'n' for nopause
<cond> =
<condition>|<code>|all: The condition is the text description for the
condition under which the alarm applies. Use the
alarm tablelist
command to find alarm conditions.
The condition code is the number of a specific alarm message. Use the
alarm
tablelist
command to find alarm condition codes.
<fac> =
The log facility (local1~local7) that has the device log the syslog
messages to different files in the syslog server. See your syslog program’s
documentation for details.
<target> =
snmp|syslog|all|none: The type of alarm messages that the device is
to send (SNMP, syslog or all).
none disables alarm reports on this alarm
category.
<clearable> =
clearable|unclearable: This sets whether or not the alarm can be
manually cleared from the system.
ras> alarm xedit sys all major local3 syslog clearable