Chapter 29 lcman Commands
Management Switch Card User’s Guide
743
The following table describes labels in the example.
The following example shows information about the line card installed in slot 1.
Table 367 lcman show Command
LABEL DESCRIPTION
id This is the slot number.
state This displays whether or not the installed card is turned on.
card type This identifies the model of card that is installed or was last installed in the slot.
uptime This is how long the card has been active.
f/w version This is the release of firmware that the card is using.
The following columns display a “V” if an alarm has been detected. “-” displays if no related
alarm has been detected.
heat This displays whether or not there is an alarm due to the cards temperature being too high or
too low.
vol This displays whether or not there is an alarm due to the card’s voltage being too high or too
low.
mon This displays whether or not the hardware monitor sensor has failed.
down This displays whether or not the installed card is down (inactive).
out This displays whether the card is installed or has been removed.
ras> lcman show 1
slot1 SLC1248G-22:
uptime: 01:33:24
status:
hardware sensor: ok
temperature : ok
voltage : ok
module exist : ok
module status : ok
inventory information:
hardware version: AA
hardware serial number: Z51854282
firmware version: V3.70(ABF.0)b5 | 11/07/2006
DSL driver version: 0.9.1.0
DSL modem version: 1.1-1.5.0__004
current voltage level: current temperature:
1.8V: 1.777 Temp1: 37.000
3.3V: 3.320 Temp2: 41.000
15.0V: 14.961 Temp3: 38.000
'*' indicates a current alarm