Zyxel IES-6000 Инструкция по эксплуатации онлайн [768/1156] 154525

Zyxel IES-6000 Инструкция по эксплуатации онлайн [768/1156] 154525
Chapter 31 port Commands
Management Switch Card User’s Guide
768
defaul
t
<slot-port>
Resets the specified subscriber port’s settings to its
defaults.
8
disabl
e
<slot-port>
Turns off a subscriber port. 8
dtpvc delete <slot-
port-vpi/vci>
Removes the specified DTPVC. 8
mvlan disable <slot-port-vpi/vci>
Turns off MVLAN for the specified DTPVC. 8
mvlan enable <slot-port-vpi/vci>
Turns on MVLAN for the specified DTPVC. 8
set <slot-port-vpi/vci>
<profile> <mux>
<svid> <spri> <cvid>
<cpri>
Configures a DTPVC on the specified subscriber
port.
8
dtpvc show <slot>|<slot-port>
Displays the DTPVC configuration for the specified
subscriber slot or port.
1
e1 alarmprof <slot-port> <profile>
Sets the alarm profile for the specified E1 port to
define the thresholds that trigger an alarm on the
port when exceeded. You can configure E1 alarm
profiles using the profile alarme1 set
command.
profile: The name of an E1 alarm profile.
8
impedance <slot-port> 75|120
Sets the E1 impedance. Use 75 for coaxial cabling
or 120 for twisted pair cabling.
8
frame <slot-port>
cas|crc|cascrc
Sets the circuit framing for the E1 line. Both peers
must use the same framing setting.
cas: Channel associated signaling.
crc: Clear channel signaling (CRC4 multiframe
format).
cascrc: Channel associated signaling (CRC4
multiframe format).
8
timingsrc <slot-port>
local|<port>
Sets the time source of the specified E1 port.
Use local to have the port use the clock of the
IMA line card. Alternatively, type the number of an
E1 port (1~8) to have the port use the clock of the
remote connected ADM device through the E1 line
you select here.
Note: This setting only works when the clock setting
of the IMA group to which the E1 port
belongs is itc. See the ima group clk
set command in Table 363 on page 721.
8
enable <slot-port>
Turns on a subscriber port. 8
enet bandwidth <slot-port> <ingress-
rate> <egress-rate>
Sets the incoming or outgoing bandwidth control
for the specified Ethernet (ELC) subscriber port(s)
(0~99968 Kbps).
ingress-rate: The incoming bandwidth rate on a
port.
egress-rate: The outgoing bandwidth rate on a
port.
8
Table 371 port Commands (continued)
COMMAND DESCRIPTION P