Yealink CP860 [172/294] Parameter permitted values descriptions web setting path

Yealink CP860 [172/294] Parameter permitted values descriptions web setting path
Yealink IP Phones Auto provisioning Guide
162
Parameter
Permitted Values
Descriptions
Web Setting Path
The default value is 0.
local_time.ntp_server1 =
IP address or
domain name
It configures the IP address or domain name
of the NTP server 1.
The default value is cn.pool.ntp.org.
Settings->Time & Date->Primary
Server
local_time.ntp_server2 =
IP address or
domain name
It configures the IP address or domain name
of the NTP server 2.
The default value is cn.pool.ntp.org.
Settings->Time & Date->Secondary
Server
local_time.interval =
Integer from 15 to
86400
It configures the update interval (in
seconds) when using the NTP server.
The default value is 1000.
Settings->Time & Date->Synchronism
(15~86400s)
local_time.summer_time =
0, 1 or 2
It enables or disables daylight saving time
(DST) feature.
0-Disabled
1-Enabled
2-Automatic
The default value is 2.
Settings->Time & Date-> Daylight
Saving Time
local_time.dst_time_type =
0 or 1
It configures the way DST works when DST
feature is enabled.
0-DST By Date
Settings->Time & Date->Fixed Type