Yealink CP860 [224/294] Parameter permitted values descriptions web setting path

Yealink CP860 [224/294] Parameter permitted values descriptions web setting path
Yealink IP Phones Auto provisioning Guide
214
Parameter
Permitted Values
Descriptions
Web Setting Path
account.X.enable =
(SIP-T28P/T48G/T46G: X ranges from 1 to 6.
SIP-T26P/T22P/ T42G/T41P: X ranges from 1 to 3.
SIP-T21P/T20P: X ranges from 1 to 2.
SIP-T19P/CP860: X=1.)
0 or 1
It enables or disables the account X.
0-Disabled
1-Enabled
The default value is 0.
Account->Register ->Line Active
account.X.label =
(SIP-T28P/T48G/T46G: X ranges from 1 to 6.
SIP-T26P/T22P/ T42G/T41P: X ranges from 1 to 3.
SIP-T21P/T20P: X ranges from 1 to 2.
SIP-T19P/CP860: X=1.)
String within 99
characters
It configures the label displayed on the LCD
screen for account X.
The default value is blank.
Account->Register ->Label
account.X.display_name =
(SIP-T28P/T48G/T46G: X ranges from 1 to 6.
SIP-T26P/T22P/ T42G/T41P: X ranges from 1 to 3.
SIP-T21P/T20P: X ranges from 1 to 2.
SIP-T19P/CP860: X=1.)
String within 99
characters
It configures the display name for account
X.
The default value is blank.
Account->Register ->Display Name
account.X.auth_name =
(SIP-T28P/T48G/T46G: X ranges from 1 to 6.
SIP-T26P/T22P/ T42G/T41P: X ranges from 1 to 3.
SIP-T21P/T20P: X ranges from 1 to 2.
String within 99
characters
It configures the user name for register
authentication for account X.
The default value is blank.
Account->Register ->Register Name