Graco Python XL 5/8" [10/48] 6 68 21 0 1

Graco Python XL 5/8
Installation
10 3A3948B
Minimum Pneumatic Pressures by Fluid Plunger Size and Outlet Pressures
See Performance Charts, starting on page 44, for maximum flows at any given pressure.
Outlet Pressure
psi (MPa, bar)
1/4 in. Fluid
Plunger Pumps
3/8 in. Fluid
Plunger Pumps
Minimum Pneumatic
Pressure
psi (MPa, bar)
Minimum Pneumatic
Pressure
psi (MPa, bar)
0 (0, 0) 15.0 (0.1, 1.0) 15.0 (0.1, 1.0)
250 (1.7, 17.2) 15.0 (0.1, 1.0) 15.0 (0.1, 1.0)
500 (3.4, 34.5) 15.0 (0.1, 1.0) 15.0 (0.1, 1.0)
750 (5.2, 51.7) 15.0 (0.1, 1.0) 15.0 (0.1, 1.0)
1000 (6.9, 68.9) 15.0 (0.1, 1.0) 15.0 (0.1, 1.0)
1250 (8.6, 86.2) 15.0 (0.1, 1.0) 15.8 (0.1, 1.1)
1500 (10.3, 103.4) 15.0 (0.1, 1.0) 18.7 (0.1, 1.3)
1750 (12.1, 120.7) 15.0 (0.1, 1.0) 21.5 (0.1, 1.5)
2000 (13.8, 137.9) 15.0 (0.1, 1.0) 24.4 (0.2, 1.7)
2250 (15.5, 155.1) 15.0 (0.1, 1.0) 27.3 (0.2, 1.9)
2500 (17.2, 172.4) 15.0 (0.1, 1.0) 30.2 (0.2, 2.1)
2750 (19.0, 189.6) 15.5 (0.1, 1.1) 33.0 (0.2, 2.3)
3000 (20.7, 206.8) 16.8 (0.1, 1.2) 35.9 (0.2, 2.5)
3250 (22.4, 224.1) 18.0 (0.1, 1.2) 38.8 (0.3, 2.7)
3500 (24.1, 241.3) 19.3 (0.1, 1.3) 41.6 (0.3, 2.9)
3750 (25.9, 258.6) 20.6 (0.1, 1.4) 44.5 (0.3, 3.1)
4000 (27.6, 275.8) 21.9 (0.2, 1.5) 47.4 (0.3, 3.3)
4250 (29.3, 293.0) 23.1 (0.2, 1.6) 50.2 (0.3, 3.5)
4500 (31.0, 310.3) 24.4 (0.2, 1.7) 53.1 (0.4, 3.7)
4750 (32.8, 327.5) 25.7 (0.2, 1.8) 56.0 (0.4, 3.9)
5000 (34.5, 344.7) 27.0 (0.2, 1.9) 58.9 (0.4, 4.1)
5250 (36.2, 362.0) 28.2 (0.2, 1.9) 61.7 (0.4, 4.3)
5500 (37.9, 379.2) 29.5 (0.2, 2.0) 64.6 (0.4, 4.5)
5750 (39.6, 396.4) 30.8 (0.2, 2.1) 67.5 (0.5, 4.7)
6000 (41.4, 413.7) 32.1 (0.2, 2.2) 70.3 (0.5, 4.8)
6250 (43.1, 430.9) 33.3 (0.2, 2.3) 73.2 (0.5, 5.0)
6500 (44.8, 448.2) 34.6 (0.2, 2.4) 76.1 (0.5, 5.2)
6750 (46.5, 465.4) 35.9 (0.2, 2.5) 78.9 (0.5, 5.4)
7000 (48.3, 482.6) 37.2 (0.3, 2.6) 81.8 (0.6, 5.6)
7250 (50.0, 499.9) 38.4 (0.3, 2.7) 84.7 (0.6, 5.8)
7500 (51.7, 517.1) 39.7 (0.3, 2.7) 87.6 (0.6, 6.0)
7750 (53.4, 534.3) 41.0 (0.3, 2.8) 90.4 (0.6, 6.2)
8000 (55.2, 551.6) 42.3 (0.3, 2.9) 93.3 (0.6, 6.4)
8250 (56.9, 568.8) 43.5 (0.3, 3.0) 96.2 (0.7, 6.6)
8500 (58.6, 586.1) 44.8 (0.3, 3.1) 99.0 (0.7, 6.8)
8750 (60.3, 603.3) 46.1 (0.3, 3.2) -
9000 (62.1, 620.5) 47.4 (0.3, 3.3) -
9250 (63.8, 637.8) 48.6 (0.3, 3.4) -
9500 (65.5, 655.0) 49.9 (0.3, 3.4) -
9750 (67.2, 672.2) 51.2 (0.4, 3.5) -
10000 (68.9, 689.5) 52.5 (0.4, 3.6) -
10250 (70.7, 706.7) 53.8 (0.4, 3.7)
10500 (72.4, 723.9) 55.0 (0.4, 3.8)
10750 (74.1, 741.2) 56.3 (0.4, 3.9)
11000 (75.8, 758.4) 57.6 (0.4, 4.0)
11250 (77.6, 775.7) 58.9 (0.4, 4.1)
11500 (79.3, 792.9) 60.1 (0.4, 4.1)
11750 (81.0, 810.1) 61.4 (0.4, 4.2)
12000 (82.7, 827.4) 62.7 (0.4, 4.3)
Outlet Pressure
psi (MPa, bar)
1/2 in. Fluid
Plunger Pumps
Minimum Pneumatic
Pressure
psi (MPa, bar)
0 (0, 0) 15.0 (0.1, 1.0)
200 (1.4, 13.8) 15.0 (0.1, 1.0)
400 (2.8, 27.6) 15.0 (0.1, 1.0)
600 (4.1, 41.4) 15.0 (0.1, 1.0)
800 (5.5, 55.2) 17.8 (0.1, 1.2)
1000 (6.9, 68.9) 21.9 (0.2, 1.5)
1200 (8.3, 82.7) 25.9 (0.2, 1.8)
1400 (9.7, 96.5) 30.0 (0.2, 2.1)
1600 (11.0 110.3) 34.1 (0.2, 2.4)
1800 (12.4, 124.1) 38.2 (0.3, 2.6)
2000 (13.8, 137.9) 42.3 (0.3, 2.9)
2200 (15.2, 151.7) 46.4 (0.3, 3.2)
2400 (16.5, 165.5) 50.4 (0.3, 3.5)
2600 (17.9, 179.3) 54.5 (0.4, 3.8)
2800 (19.3, 193.1) 58.6 (0.4, 4.0)
3000 (20.7, 206.8) 62.7 (0.4, 4.3)
3200 (22.1, 220.6) 66.8 (0.5, 4.6)
3400 (23.4, 234.4) 70.8 (0.5, 4.9)
3600 (24.8, 248.2) 74.9 (0.5, 5.2)
3800 (26.2, 262.0) 79.0 (0.5, 5.4)
4000 (27.6, 275.8) 83.1 (0.6, 5.7)
4200 (29.0, 289.6) 87.2 (0.6, 6.0)
4400 (30.3, 303.4) 91.3 (0.6, 6.3)
4600 (31.7, 317.2) 95.3 (0.7, 6.6)
4800 (33.1, 330.9) 99.4 (0.7, 6.9)