Moxa WAC-1001 [7/56] Environmental limits

Moxa WAC-1001 [7/56] Environmental limits
WAC-1001 Introduction
1-3
Product Specifications (WAC-1001 Rev 2.xx.x)
WLAN Interface
Standards:
IEEE
802.1x (Radius client)
IEEE 802.3u for 10/100BaseT(X) for Ethernet
LAN
IEEE 802.3af for Power
-over-Ethernet
Supported Models:
• AWK
-3121-M12-RTG
AWK-3121-SSC-RTG
Interface
LAN Ports:
1, 10/100/1000BaseT(X), auto negotiation speed (RJ45-type)
Console for External Antenna:
RS-232 (RJ45-type)
LED Indicators:
PWR1, PWR2, PoE, FAULT, STATE, LAN
Alarm Contact:
1 relay output with current carrying capacity of 1 A @ 24 VDC
Digital Inputs:
2 electrically isolated inputs
• +13 to +30 V for state “1” (ON)
• +3 to
-30 V for state “0” (OFF)
• Max. input current: 8 mA
Physical Characteristics
Housing:
Metal, providing IP30 protection
Weight:
1060 g
Dimensions:
52.85 x 135 x 105 mm (2.08 x 5.31 x 4.13 in)
Installation:
DIN-Rail mounting, wall mounting (optional)
Environmental Limits
Operating Temperature:
Standard Models: 0 to 60°C (32 to 140°F)
Wide Temp. Models:
-40 to 75°C (-40 to 167°F)
Storage Temperature:
-40 to 85°C (-40 to 185°F)
Ambient Relative Humidity:
5 to 95% (non-condensing)
Power Requirements
Input Voltage:
12 to 48 VDC, redundant dual DC power inputs or 48 VDC Power-over-
Ethernet (IEEE 802.3af
compliant)
Connector:
10-pin removable terminal block, 500 V insulation
Power Consumption:
Max. 7.2 W (12V/0.6A to 48V/0.15A), 25°C
Reverse Polarity Protection:
Present
Standards and Certifications
Safety:
UL 60950-1, EN 60950-1
EMC:
EMI: CISPR 22, FCC Part 15B Class B
EMS:
EN 61000-6-2/61000-6-4
IEC 61000-4-2 ESD: Contact 8 kV; Air 15 kV
IEC 61000-4-3 RS: 10 V/m (80 MHz to 1 GHz)
IEC 61000-4-4 EFT: Power 2 kV; Signal 1 kV
IEC 61000-4-5 Surge: Power 2 kV; Signal 1 kV
IEC 61000-4-6 CS: 10 V
IEC 61000-4-8
Note: Please check Moxa’s website for the most up
-to-date certification status.
Warranty
Warranty Period:
5 years
Details:
See www.moxa.com/warranty