Moxa V2616A-C5 [8/44] Power requirements

Moxa V2616A-C5 [8/44] Power requirements
V2616A Hardware Manual Introduction
1-4
Operating Temperature: (without HDD installed)
Standard models: -25 to 55°C (-13 to 131°F)
Wide temp. models: -40 to 70°C (-40 to 158°F)
Storage Temperature: (with SSD installed) -40 to 85°C (-40 to 185°F)
Ambient Relative Humidity: 5 to 95% (non-condensing)
Anti-vibration: EN 50155 standard
Anti-shock: EN 50155 standard
Power Requirements
Input Voltage: 24 to 110 VDC, M12 connector
Note: 24 and 110 VDC are EN 50155 compliant
Power Requirements:
• 60 W (no SSD/HDD attached)
• 2.5 A @ 24 VDC to 0.55 A @ 110 VDC (no SSD/HDD attached)
Power Button: On/off (rear panel)
Standards and Certifications
Safety: UL 60950-1, CSA C22.2 No. 60950-1-07, EN 60950-1
EMC: EN 55022 Class A, EN 61000-3-2 Class D, EN 61000-3-3, EN 55024, FCC Part 15 Subpart B Class A
Rail Traffic: EN 50155 (essential compliance*), EN 50121-3-2, EN 50121-4, IEC 61373
Green Product: RoHS, CRoHS, WEEE
*Please contact Moxa or a Moxa distributor for details.
Reliability
Automatic Reboot Trigger: Built-in WDT (watchdog timer) supporting 1-
255 second system reset, software
programmable
Warranty
Warranty Period: 3 years
Details: See www.moxa.com/warranty
Note: These hardware specifications describe the embedded computer unit itself, but not its official
accessories. In particular, the wide temperature specification does not apply to accessories such as power
adapters and cables.