Moxa TC-6110-T-LX [9/46] Environmental limits

Moxa TC-6110-T-LX [9/46] Environmental limits
TC-6110 Series Hardware Introduction
1-6
Physical Characteristics
Housing:
Aluminum and SECC sheet metal (1 mm)
Weight:
5 kg (11.11 lb)
Dimensions:
• Without ears: 210 x 222 x 133 mm (8.27 x 8.74 x 5.24 in)
• With ears: 210 x 269 x 133 mm (8.27 x 10.60 x 5.24 in)
Mounting:
Rack
Environmental Limits
Operating Temperature:
• Standard models:
-25 to 55°C (-13 to 140°F), (EN 50155 Class T1)
• Wide temp. models:
-40 to 70°C (-40 to 158°F), (EN 50155 Class Tx)
Storage Temperature:
-40 to 85°C (-40 to 185°F)
Ambient Relative Humidity:
5 to 95% (non-condensing)
Anti
-Vibration: Meets EN 50155 standard
Anti
-Shock: Meets EN 50155 standard
Power
Reset Button:
For warm reboot (front panel)
Input Voltage:
24 to 110 VDC; A-coded, 5-pin, male M12 connector
Power Consumption:
32 W (without heater), 62 W (with heater), no SSD/HDD attached
Note: 24 VDC and 110 VDC compliant with EN 50155
Standards and Certifications
Safety:
UL 60950-1, CSA C22.2 No. 60950-1-07, EN 60950-1
EMC:
EN 55022:2010 Class A, EN 55024:2010, FCC CFR Title 47 Part 15 Subpart B: 2011 Class A, CISPR
22:2008, ANSI C63.4:2009, ICES
-003 Issue 5:2012 Class A
RF:
EN 62311:Jan 2008, ETSI EN 301 489-1:V1.9.2 (2011-09), ETSI EN 301 489-3:V1.4.1 (2002-
08), ETSI EN
301 893:V1.6.1 (2011
-11), ETSI EN 300 328:V1.7.1 (2006-10), ETSI EN 300 440-1:V1.6.1 (2010-
08), ETSI
EN 300 440
-2:V1.4.1 (2010-08)
Rail Traffic:
EN 50155:2007 (essential compliance*), EN 50121-1:2006 for EMC test, EN 50121-3-
2:2006, EN
50121
-4:2006, EN 5011:2009+A1:2010, EN 61000-6-4:2007, CISPR 16-1-2:2003/A2:2006, CISPR
16
-2-1:2003+A1:2005, CISPR 16-2-3:2006, EN 60068-2-1:2007, EN 60068-2-2:2007, EN 61373:1999
*Moxa defines “essential compliance” to include those EN 50155 requirements that make products
more suitable for rolling stock railway applications.
Environmental Tests: EN 60068-2-1:2007, EN 60068-2-2:2007, EN 61373:1999
Reliability
Automatic Reboot Trigger:
Built-in WDT (watchdog timer) supporting system reset with software
programmable time intervals of 1
-255
MTBF (mean time between failures)
Time:
360,616 hrs
Standard:
Telcordia (Bellcore) Standard TR/SR
Warranty
Warranty Period:
3 years
Details:
See www.moxa.com/warranty
Note: These hardware specifications describe the embedded computer unit itself, but not its official
accessories. In particular, the wide temperature specification d
oes not apply to accessories such as power
adapters and cables.