Moxa MxNVR-MO4 [50/61] Schedule

Moxa MxNVR-MO4 [50/61] Schedule
Moxa MxNVR-IA8 System Configuration
4-21
Basic
Alarm Time Interval
Setting Description Default
Delay second(s) before
detecting the next
alarm
Set the minimum time interval before another event alarm is
triggered.
32 seconds
(10 to 999 seconds)
NOTE The delay before triggering the next alarm cannot be less than the time needed to do the video recording
when
an event happens.
DI, DO Status
The Administrator can check the current DI and relay status of the MxNVR in the “DI, DO Status” section on the
Event Alarm Basic Settings page. Two options are available to restore the relay status back to the system
defaults. To enable the function, check the Override DO 1 warning setting and Override DO 2 warning
setting boxes, and then click on Save.
NOTE The DOs will not be triggered if
the Override DO 1 warning setting and Override DO 2 warning setting boxes are
checked. Un-check these two boxes to ensure that the relays will be triggered.
Schedule
A schedule is provided to set event alarms accordingly for daily security applications.