Chapter 3: BIOS Setup
Chapter 3
Chassis Fan 1/2 Middle Temperature [45]
Use the <+> or <-> keys to set the value for Chassis Fan Middle
Temperature.
Chassis Fan 1/2 Middle Duty Cycle(%) [60]
Use the <+> or <-> keys to adjust the chassis fan middle duty cycle. The
values range from 60% to 100%.
Chassis Fan 1/2 Lower Temperature [40]
Use the <+> or <-> keys to adjust the chassis fans’ lower temperature. The
values range from 40°C to 75°C.
Chassis Fan 1/2 Min. Duty Cycle(%) [60]
Use the <+> or <-> keys to adjust the minimum chassis fan duty cycle. The
values range from 60% to 100%. When the chassis temperature is under
the lower limit, the chassis fan operates at the minimum duty cycle.
AIO_PUMP/W_PUMP+ Control [Disabled]
Use the <+> and <-> keys to adjust the AIO_PUMP/W_PUMP+ control. The values
range from 20% to 100%. When the AIO_PUMP/W_PUMP+ temperature is under the
lower limit, the AIO_PUMP/W_PUMP+ fan will operate at the minimum duty cycle.
[Auto] Enables the AIO_PUMP/W_PUMP+ control for 4-pin CPU fan.
[Disabled] Disables the AIO_PUMP/W_PUMP+ control feature.
[DC Mode] Enable the AIO_PUMP/W_PUMP+ control in DC mode for 3-pin
AIO_PUMP/W_PUMP+ fan.
[PWM Mode] Enable the AIO_PUMP/W_PUMP+ control in PWM mode for 4-pin
AIO_PUMP/W_PUMP+ fan.
The following items appear only when you set the AIO_PUMP/W_PUMP+ Control to
[Auto], [PWM Mode] or [DC Mode].
AIO_PUMP/W_PUMP+ Upper Temperature [70]
Use the <+> or <-> keys to adjust the upper limit of the AIO_PUMP/W_
PUMP+ temperature. The values range from 40°C to 75°C.
AIO_PUMP/W_PUMP+ Max. Duty Cycle(%) [100]
Use the <+> or <-> keys to adjust the maximum AIO_PUMP/W_PUMP+
duty cycle. The values range from 60% to 100%. When the AIO_PUMP/W_
PUMP+ temperature reaches the upper limit, the AIO_PUMP/W_PUMP+
fan will operate at the maximum duty cycle.
AIO_PUMP/W_PUMP+ Middle Temperature [45]
Use the <+> or <-> keys to set the value for AIO_PUMP/W_PUMP+ Middle
Temperature.
AIO_PUMP/W_PUMP+ Middle Duty Cycle(%) [60]
Use the <+> or <-> keys to adjust the AIO_PUMP/W_PUMP+ middle duty
cycle. The values range from 60% to 100%.
AIO_PUMP/W_PUMP+ Lower Temperature [40]
Use the <+> or <-> keys to adjust the AIO_PUMP/W_PUMP+’ lower
temperature. The values range from 40°C to 75°C.
AIO_PUMP/W_PUMP+ Min. Duty Cycle(%) [60]
Use the <+> or <-> keys to adjust the minimum AIO_PUMP/W_PUMP+
duty cycle. The values range from 60% to 100%. When the AIO_PUMP/W_
PUMP+ temperature is under the lower limit, the AIO_PUMP/W_PUMP+
fan operates at the minimum duty cycle.