EN – Instruction manual
Proper use
The radiator may only be used to heat
indoor areas.
Any other use is improper and is therefore pro-
hibited.
Improper use
The radiator is not suitable for use as a seat or
as a climbing or mounting aid.
Safety precautions
WARNING
Risk of burns!
The radiator surface can reach temperatures
of up to 110 °C (230 °F).
Take care when touching the radiator.
CAUTION
Risk of scalding when bleeding due to hot
water spraying out!
Protect your face and your hands.
Maintenance
Bleed the radiator after commissioning and
after longer interruptions in operation.
Use a standard radiator bleeding key.
Cleaning
Only use mild, non-scouring cleaning
agents.
Complaints
Contact your specialised tradesman.
Installation and repair
Installation and repair should only be per-
formed by a specialised tradesman so that
warranty claims remain valid.
Disposal
Take disused radiators with accessories to a
recycling centre or authorised waste man
-
agement facility. Observe local regulations.
EN – Installation manual
The radiator may only be installed by a special-
ised tradesman.
Safety precautions
Read these instructions thoroughly before
installation/commissioning.
After installation, hand over the manual to
the end user.
WARNING
Danger of injury!
Take the weight of the radiator into ac-
count (see manufacturer documenta-
tion).
Work with lifting equipment or several
persons for weights from 25 kg.
Conditions of use
Follow local regulations on operating con-
ditions and water quality.
Observe the limitations on use in damp
rooms in accordance with local conditions.
Only use the radiator in closed heating sys
-
tems.
Only transport and store the radiator in the
protective packaging.
Observe the minimum distances between
the radiator and ambient parts to ensure
air circulation.
Complaints
Contact the supplier.
Disposal
Take the packaging and parts not required
to a recycling centre or authorised waste
management facility. Observe the local
regulations.
Technical characteristics
Operating pressure: max. 10 bar
Test pressure: 13 bar
Supply temperature: Hot water up to 110 °C
(230 °F)