15
Use the up and down keys to select the password “65
Press the on/sby/enter key to confirm your selection.
If the password is correct, the display shows the first parameter in the configuration list.
Use the up and down keys to scroll the controller parameters
Press the on/sby/enter key to confirm your selection.
Use the keys up and down to select the new value
Press the on/sby/enter key to confirm your selection.
You can leave the programming phase by waiting for 30 seconds without operating on the card, or pressing for 5 seconds.
In both cases, there you will hear 3 consecutive, short beeps and the display will temporarily show [ESC].
PARAMETERS OF CONFIGURATION
Parameter
Description
Default
-2°C/+8°C
Default
-12°C/-24°C
MAX
MEASUREMENT INPUTS
/1
Room probe calibration (the parameter is expressed in eighths of degree)
+8°C
-4°C
+99
/2
evaporator probe activation (0=off;1=on)
1
1
0
/3
condenser probe activation (0=off; 1=on)
0
0
0
/9
aux. output setting : 0 = door resist.; 1 = light com.
0
0
0
/A
door resist. activation setpoint (only if /9 =0)
-7°C
-7°C
+99
/b
door resist. activation adjustment hysteresis (only if /9 =0)
2°C
2°C
15
Pr
room probe reading
- °C
- °C
-
Pd
defrost probe reading
- °C
- °C
-
Pc
room probe reading
- °C
- °C
-
COMPRESSOR ADJUSTMENT, ENERGY SAVING, HIPER COLD
r0
adjuster hysteresis (differential)
+4°C
+4°C
15
r1
min. operating setpoint selectable
-2°C
-24°C
r2
r2
max. operating setpoint selectable
+8°C
-12°C
+99
r3
temperature increase above setpoint for energy saving :
0= excluded
+1°C
+2°C
+99
r4
monitoring time for energy saving start
2 ore
2 ore
99
r5
temperature decrease below setpoint for hiper cold : 0= excluded
-2°C
-2°C
0
r6
time limit of setpoint persistence in hiper cold
2 ore
2 ore
99
r7
time deviation allowed as to comp. cycle ON. Optimum
1 min
1 min
240
r9
min. t as to comp. cycle ON for non-efficient cycle definition
1 min
1 min
240
rA
max. t as to comp. cycle ON beyond which the cycle is not consid.
5 min
5 min
240
rb
min. time deviation allowed for Te function
5°C/min
5°C/min
+99
rc
max. number of low-efficient compressor cycles
3 nr.
3 nr.
3
rL
max. time limit for defrost start in the first phase (0= excluded)
120 min
120 min
240
COMPRESSOR PROTECTION
C0
compressor activation delay from device start
1 min
1 min
240
C2
min. delay between compr. stop and subsequent start
3 min
3 min
240
C5
compressor start cycle time in the event of room probe alarm
10 min
10 min
240
C6
C5 % where compr. starts in the event of room probe alarm
50 %
70 %
100
DEFROST
d0
defrost interval (0= excluded)
6 ore
6 ore
99
d1
defrost type (0= resistance, 1= hot-gas)
0
0
1
d2
end-of-defrost temp. (relating to evaporator temper.)
+8 °C
+8 °C
+99
d3
max. defrost duration (0= defrost never activated)
30 min
30 min
99
d6
defrosting display (0=actual cell temperature,
1=stopped cell temperature, 2=dEF label)
1
1
2
d7
dripping time
3 min
3 min
15