La Nordica Fly Idro D.S.A белая [19/64] Chimney pot

La Nordica Fly Idro D.S.A белая [19/64] Chimney pot
FLY IDRO DSA
7193505 - IT-EN-DE-FR 19
that the ash does not obstruct the entry of the primary air for the combustion.
In order to open the air ow, the bar must be completely pulled out.The primary air register must be almost completely closed during
wood combustion, as otherwise the wood burns too quickly and the thermo-product may overheat.
2A- SECONDARY air register (Picture 7 at page 55).
Below the hearth door, on the right front side there is the secondary air register.
The secondary air, passing through the two lateral jambs of the front side, heats itself starting the double combustion and keeping at
the same time the glass clean ( with open register).
When the bar is pushed to the back the passage of the secondary is completely open.
The adjustment of the registers necessary to reach the rated caloric yield is the following one:
Fuel PRIMARY air SECONDARY air TERTIARY AIR
FLY IDRO - DSA
Wood CLOSED 1/2 OPEN PRE-ADJUSTED
5. FLUE
Essential requirements for correct appliance operation:
the internal section must preferably be circular;
the appliance must be thermally insulated and impermeable and built with suitable materials which are resistant to heat, combustion
products and any condensation;
there must be no narrowing and vertical passages with deviations must not be greater than 45°;
if already used, it must be clean;
the technical data from the instruction manual must be respected;
If the ues are of a square or rectangular section, the internal edges must be rounded with a radius of not less than 20 mm.
For the rectangular section, the maximum ratio between the sides must be ≤ 1.5.
A section which is too small causes a reduction in draught. A minimum height of 4 m is advisable.
The following materials are FORBIDDEN and compromise the good operation of the appliance: asbestos cement, galvanised steel, rough
and porous internal surfaces. Picture 2 at page 52 shows some example solutions.
The minimum section must be 4 dm
2
(for example 20x20 cm) for appliances whose pipe dimensions are less than 200 mm, or 6.25
dm
2
(for example 25x25 cm) for appliances with a diameter of more than 200 mm.
The draught created by your ue must be sufcient but not excessive.
A section of the ue which is too large can present a volume which is too large to heat and therefore cause operating difculties for the
appliance; to avoid this, it is necessary to intubate the appliance for its entire height. A section which is too small causes a reduction in
draught.
The ue must be at a suitably distance from ammable or combustible material using suitable insulation or an air space.
It is FORBIDDEN to pass system piping or air ducts inside the ue. It is also forbidden to create moveable or xed openings on the ue
itself, for the connection of further different appliances (See chapter CONNECTING A FIREPLACE OR OPEN HEARTH TO THE FLUE).
5.1. CHIMNEY POT
The ue draught depends on the suitability of the chimney pot.
It is therefore essential that, if built in a handcrafted way, the exit section is more than twice the internal section of the ue
(Picture 3 at page 52) .
As it must always go past the ridge of the roof, the chimney pot must ensure exhaust even in the presence of wind (Picture 4 at page 53).
The chimney pot must meet the following requirements:
Have an internal section equivalent to that of the chimney.
Have a useful exit section of double the internal section of the ue.
Be built so as to prevent rain, snow or any foreign body entering the ue.
Be easy to inspect, for any maintenance and cleaning operations.
5.2. CONNECTION TO THE CHIMNEY
Products with automatic door closing (type 1) must operate, for safety reasons, with the furnace door closed (except during the fuel loading
or ash removal phases).
Products with non-automatic door closing (type 2) must be connected to their own ue.
Operation with doors open is only allowed when supervised.
The connection pipe to the ue must be as short as possible, straight horizontal and positioned slightly in ascent, and watertight.
Connection must be carried out with stable and robust pipes (we recommend a thickness of 2 mm) and be hermetically secured to the ue.
The internal diameter of the connection pipe must correspond to the external diameter of the cooker ue gas exhaust stub pipe (DIN 1298).
ATTENTION: as far as concern the realisation of the ue connection and ammable materials please follow the requirements provided by
UNI 10683 standard. The ue must be properly spaced from any ammable materials or fuels through a proper insulation or an air cavity.
For a better working of the appliance, it is suggested to have a ue draught of 17 - 20 Pascal (= 1,7 - 2,0 mm of column of water).
The measurement has always to be carried out with hot device (rated thermal performance).
When the depression exceeds 20 Pa (=2,0 mm of column of water), it is necessary to reduce the same by installing an additional draught
regulator (buttery valve) on the exhaust pipe or in the chimney, according to the regulations in force.