Tp-Link TL-ER6120 Инструкция по эксплуатации онлайн [33/167] 39127

-28-
Auth Server:
Enter the address of authentication server. It can be IP
address or server name.
Auth Domain:
Enter the domain name of authentication server. It's only
required when the address of Auth Server is a server
name.
Auth Mode:
You can select the proper Active mode according to your
need.
z Manual: Select this option to manually activate or
terminate the Internet connection by the <Connect>
or <Disconnect> button. It’s optimum for the dial-up
connection charged on time.
z Always-on: Select this option to keep the
connection always on. The connection can be
re-established automatically when it is down.
MTU:
MTU (Maximum Transmission Unit) is the maximum
data unit transmitted by the physical network. It can be
set in the range of 576-1500. The default MTU is 1500.
Upstream/Downstream
Bandwidth:
Specify the Upstream/Downstream Bandwidth for the
port. To make "Load Balance" and "Bandwidth Control"
take effect, please set these parameters correctly.
¾ BigPond Status
Status:
Displays the status of BigPond connection.
z “Disabled” indicates that the BigPond connection type
is not applied.
z “Connecting” indicates that the Router is obtaining the
IP parameters from your ISP.
z “Connected” indicates that the Router has
successfully obtained the IP parameters from your
ISP.
z “Disconnected” indicates that the connection has been
manually terminated or the request of the Router has

Содержание