Tektronix MSO64 [138/628] Display instantaneous power and energy plots from the power quality measurement

Tektronix MSO64 [138/628] Display a power switching loss swl trajectory plot
The Inductance Curve plot is displayed in a separate Plot view.
3. Double-tap in the Plot view to open the configuration menu for that plot.
Display a Safe Operating Area (SOA) measurement and plot
Use this procedure to display a SOA plot. This is an XY plot with a mask. Requires option 5-PWR or 6-PWR.
To display an SOA power measurement and plot:
1. Tap the Add New... Measurement button.
2. Tap the Power tab.
3. Set the voltage and current sources for the measurement.
4. Tap the Switching Analysis panel.
5. Select the SOA measurement and tap Add.
The SOA measurement adds a Power measurement badge to the Results bar, and automatically adds the SOA plot to the
screen.
6. Double-tap in the Plot view to open a configuration menu for that plot.
Display a power Switching Loss (SWL) Trajectory plot
Use this procedure to display a trajectory plot for a power measurement. Requires option 5-PWR or 6-PWR.
To display a trajectory power plot, you must be taking a Switching Loss measurement (Add New... Measurement > Power tab >
Switching Analysis panel > Switching Loss measurement).
1. Double-tap the Switching Loss measurement badge to open the configuration menu.
2. Tap Trajectory Plot to add a new Trajectory Plot view to the screen.
3. Double-tap in the Plot view to open a configuration menu for that plot.
Display instantaneous power and energy plots from the Power Quality
measurement
Use this procedure to display a power/energy plot from the Power Quality measurement. Requires option 5-PWR or 6-PWR.
To display the power and energy plots you must be taking the Power Quality measurement.
1. Tap the Add New... Measurement button.
2. Tap the Power tab.
3. Set the Voltage and Current sources for the measurement.
Analog channel operating basics
108 4/5/6 Series MSO Help