Tektronix MSO64 — настройка I3C серийной шины: руководство по конфигурации [284/628]

Tektronix MSO58 [284/628] I3c serial bus configuration menu
See also.
Bus Trigger configuration on page 432
Bus Search configuration menus on page 282
I3C serial bus configuration menu
Use the I3C bus menu (optional) to set up and display a decoded I
3
C serial bus waveform.
To set up the I
3
C serial bus menu:
To create a new I
3
C bus waveform, tap the Add New Bus button on the Settings bar. Open the bus configuration menu by
double clicking on the badge. Set the Bus Type to I3C.
To change the settings on an existing I
3
C serial bus waveform, double-tap the I
3
C Bus waveform badge and make
necessary changes in the configuration menu.
I3C serial bus menu fields and controls.
Field or control Description
Display Turns On or Off displaying the bus on the Waveform view.
Label Creates a label for the bus. The default label is the selected bus type.
To enter label text, double-tap the field and enter label using the virtual keyboard, or tap the
field and enter text from an attached keyboard.
Position Sets the vertical position of the bus waveform. The default position is vertically centered in a
slice (in Stacked mode), or center screen in Overlay mode. The unit of position is screen
divisions.
Set to 0 Sets the vertical position to 0 divisions (centered vertically in a slice or on the screen.
Bus Type Set to I3C.
SCLK Input Sets the source and threshold level for the Serial Clock Line signal.
SDA Input Sets the source and threshold level for the Serial Data signal.
Display Format Sets the waveform view to show just the decoded bus information, or the decoded bus plus the
source signal waveforms.
Decode Format Sets the decode format used to display the bus information. Formats are Hex, Binary, and
Mixed Hex.