Emotron CDU/CDX 48-037 [22/82] Encoder

Emotron CDU/CDX 48-008 [22/82] Encoder
EMOTRON DSV 5445/5444
Page 22
Emotron 21.04.09
5 Encoder
5.1 Pin assignment of rotational encoder and connector X3
X3 pin Pin assignment
at connector X3
of the DSV 5445
Encoder type
1Vpp 4 tracks
Ub=5V
Encoder type
TTL 4 tracks
Ub=5V
Encoder type
TTL 4 tracks
Ub=10...30V
Encoder type
HTL 2 tracks
Ub=10...30V
No encoder
(Emergency
operation)
1 A A A A A
2 /A /A /A /A
3 5 VDC 5 VDC 5 VDC
4 GND GND GND GND
5 B B B B B
6 /B /B /B /B
7 N N ** N ** N ** N **
8 /N /N ** /N ** /N **
9 Inner screen
10 -15 VDC -15 VDC
11 GND SENSE -sense ** -sense **
12 Outer screen Screen Screen Screen Screen
13 VCC SENSE +sense ** +sense **
14 Alarm
15 +15 VDC +15 VDC +15 VDC
Jumper position on the
controller board (JP3)
JP3-Flag 0E3E 0 255 255 255 (0E60=255)
The table shown above is valid for elevator plants using asynchronous motors.
** = N, /N and sense-control should only connected if used encoder has that function and cables!
For synchronous motors, option SSI, EnDat ®, second encoder ATB-version or resolver
please note the specification for termination and setting in the respective chapter.
5.1.1 Jumper JP3
Hardware encoder monitoring: top
1Vpp sine; bottom
4 channel TTL
centre
no monitoring HTL or in case of resolver-card
If the jumper JP3 must be changed, check also the JP3-flag in variables: 1Vpp sine "0E3E = 0",
TTL/HTL "0E3E = 255"! (Note: for encoderless driving the service-flag 0E60 must set from 0 to 255)
Pic.: Position jumper JP3 size 2-5; In case of size 1 and size 2 flat the housing has to be opened.