3.2.1 Power connection and accessories
DSV 5445
I
dyn
[A] Output
power
[kVA]
Power
loss
[kW]
Airflow
[m³/h]
Motor type
[kW]
Network-
fuse
type gL
RFI
motor
filter
AddOn
Line
reactors
(typically)
Conductor
cross-section
mains/motor
lines
Brake resistor
Approx. 6
mounting
pedestals
Cable cross-
section
5/10
10/20 6,5
0,19
27
3,0 - 5,5
3 × 10A
Bgr. 1
3×1,5 mH, 16A
4 x 1,5 mm² *
40 / 0.5 kW
2. x.1,5 mm²
15
24 10
0,30
27
4,0-7,5
3 × 16A
Bgr. 1
3×1,5 mH, 16A
4 x 1,5 mm² *
40 / 1 kW
2. x.1,5 mm²
20
30 13,0
0,41
112
5,5 - 9,0
3 × 25A
Bgr. 2
3×0,7 mH, 35A
4 x 2,5 mm² *
40 / 1 kW
2. x.1,5 mm²
30
45 19,5
0,58
112
7,5 - 15,0
3 × 35A
Bgr. 2
3×0,7 mH, 35A
4 x 4,0 mm² *
18-20 / 2 kW
2. x.2,5 mm²
40
60 26,0
0,75
112
11 - 22
3 × 50A
Bgr. 3
40A
3×0,5 mH, 50A
4 x 6,0 mm² *
18-20 / 2 kW
2. x.2,5 mm²
60/
70
90/
100
39,0/
45,5
1,2
112
22 - 30
3 × 63A
Bgr. 3
60A
3×0,3 mH, 80A
4 x 16 mm² *
14-15 / 4 kW
2. x.2,5 mm²
80
120 52,0
1,5
490
30 - 45
3 × 80A
Bgr. 4
Typ 2
3×0,25 mH. 100A
3×0,3 mH, 80A
4 x 25 mm² *
14-15 / 4 kW
2. x.2,5 mm²
120
180 78,0
2,25
490
45 - 55
3 × 125A
Bgr. 4
Typ 3
3×0,18 mH, 130A
3×0,25 mH, 100A
4 x 35 mm² *
13 / 6,5 kW
2. x.4,0 mm²
150
225 104,0
3,0
490
55 -75,0
3 × 160A
Bgr. 4
Typ 3
3×0,12 mH 200A
3×0,18 mH, 130A
4 x 50 mm² *
10 / 8 kW
2. x.4,0 mm²
150
1)
225 104,0
3,0
810
55 -75,0
3 × 160A
Bgr. 5
3×0,12 mH 200A
3×0,18 mH, 130A
4 x 50 mm² *
10 / 8 kW
2. x.4,0 mm²
200
300 138,5
4,0
810
90-110
3 × 200A
Bgr. 5
3×0,12 mH 200A
4 x 70 mm² *
6,5 / 11 kW
2. x.6,0 mm²
250
375 173,5
5,0
810
132
3 × 250A
Bgr. 5
3×0,10 mH 250A
3×0,12 mH 200A
4 x 70 mm² *
4,0 / 13 kW
2. x.10,0 mm²
320
480 222,0
6,0
810
160
3 × 320A
Bgr. 5
3×0,10 mH 250A
3×0,093mH 315A
4 x 95 mm² *
2,5 / 19 kW
2. x.25,0 mm²
Motor type
[KW]
The allocation DSV 5445 to motor power has to be verified by means of the lift
data!
Network fuse
The type "gL" can be used for the network fuse. In case of using semiconductor
fuses the nominal current has to be increased.
Line reactors
Depending on the operating time, mechanical and electrical specifications of the
system the nominal data of the line reactor can drift.
Conductor cross-
section:
The given cross-sections are standard values regardless the ambient conditions,
used cable types and network fuses. Because of this the cross-sections can vary
depending on the applicable regulations.
Installation position
As pictures s. chapter 13, perpendicularly connecting terminals left
Installation distances
Min. 100mm upward and downward, min. 10mm sideways
Brake resistor
The dimensioning of the brake resistor has to be verified by means of the lift data!
DSV 5445 Size 2 flat
The values are according to the table above.
1)
DSV 5445 150/400 BGR 5 is an old type (don’t use it for new applications, if the BGR 4 can be used here).
GSV 5445 – series: See separate manual for DC-brushed motors!