Tecorp HC2V9G4220 Инструкция по эксплуатации онлайн [75/182] 475051

Tecorp HC2V8G22P2 Инструкция по эксплуатации онлайн [75/182] 474977
High Performance Vector Control/Torque Control Inverter User Manual
Chapter 5 List of Parameters 53
PA.07 Energy saving coefficient 0 0 ~ 50 % 0 ~ 50%
PA.08
Magnetic flux braking
selection
1 0 ~ 1 / ×
0: Disabled;
1: Enabled
PA.09
Energy sonsumption
braking selection
0 0 ~ 1 / ×
0: Disabled;
1: Enabled
PA.10 Braking unit operating time
100.0
100.0 s ×
100.0s(Total cycle working time
and interval is 100s)
PA.11 Braking unit action voltage
750
650 ~ 750 V × 650 ~ 750V
PA.12
Relay action indication
when the inverter is faulty
100
000 ~ 111 / ×
LED ones place: Under volt fault
0: Disabled; 1: Enabled
LED tens place: Auto reset
interval
0: Disabled; 1: Enabled
LED hundreds place: Fault
locking
0: Disabled; 1: Enabled
PA.13
Inverter or motor overload
prealarm
000
000 ~ 111 / ×
LED ones place: Selection of
detected value
0: Motor overload pre-alarm,
relative to motor rated current;
1: Inverter overload pre-alarm,
relative to inverter rated current;
LED tens place: Action selection
after overload pre-alarm
0: Continue running;
1: Report overload fault and st
op;
LED hundreds place: Detecting
condition selection
0: Detect all the time;
1: Only detect at constant speed
PA.14
Overload pre-alarm
detection level
130.0
20.0 ~ 200.0
% × 20.0 ~ 200.0%
PA.15
Overload pre-alarm
detection time
5.0
0.1 ~ 60.0 s × 0.1 ~ 60.0s
PA.16
Fault shield and alarm
attribute setting 1
0020
0000 ~ 2222
/ ×
LED ones place: Output-ground
short circuit
LED tens place: Power failure
during running process
LED hundreds place: Input power
error
LED thousands place: Output
phase failure
0: Fault is not shileded, stopped
upon fault;
1: Fault is not shielded, non-stop
upon fault;
2: Fault is shielded
, no alarm and
no stop
PA.17
Fault shield and alarm
attribute setting 2
0000
0000 ~ 2222
/ ×
LED ones place: EEPROM error
LED tens place: Relay contact
open/close failure
LED hundreds place:
Temperature sampling
disconnection
LED thousands place: encoder
disconnection
0: Fault is not shileded, stopped
upon fault;
1: Fault is not shielded, non-stop
upon fault;
2: Fault is shielded, no alarm
and
no stop

Содержание

Скачать