Tecorp HC2V9G4220 [74/182] Group pa control parameter

Tecorp HC2V8G4030 [74/182] Group pa control parameter
High Performance Vector Control/Torque Control Inverter User Manual
52 Chapter 5 List of Parameters
P9.02
Rated rotating velocity of
motor
1500
0 ~ 30000 rpm
× 0 ~ 30000rpm
P9.03 Rated power of motor 11.0
0.4 ~ 999.9
kW
× 0.4 ~ 999.9kW
P9.04 Rated current of motor 21.7
0.1 ~ 999.9
A × 0.1 ~ 999.9A
P9.05 Zero load current I0 8.4
0.1 ~ 999.9
A × 0.1 ~ 999.9A
P9.06 Stator resistance R1 0.407
0.000 ~ 65.000
× 0.000 ~ 65.000Ω
P9.07
Stator leakage inductance
L1
2.6
0.0 ~ 2000.0
mH
× 0.0 ~ 2000.0mH
P9.08 Rotor resistance R2 0.219
0.000 ~ 65.000
× 0.000 ~ 65.000Ω
P9.09 Mutual inductance L2 77.4
0.0 ~ 2000.0
mH
× 0.0 ~ 2000.0mH
P9.10
Magnetic saturation
coefficient 1
87.00
0.00 ~ 100.00
% × 0.0 ~ 100.00%
P9.11
Magnetic saturation
coefficient 2
80.00
0.00 ~ 100.00
% × 0.0 ~ 100.00%
P9.12
Magnetic saturation
coefficient 3
75.00
0.00 ~ 100.00
% × 0.0 ~ 100.00%
P9.13
Magnetic saturation
coefficient 4
72.00
0.00 ~ 100.00
% × 0.0 ~ 100.00%
P9.14
Magnetic saturation
coefficient 5
70.00
0.00 ~ 100.00
% × 0.0 ~ 100.00%
P9.15 Parameter auto tuning 0 0 ~ 2 / ×
0: No action;
1: Static auto tuning;
2: Rotating auto tuning
P9.16 Motor overload protection
00
0 ~ 12 / ×
Ones place: Protection mode;
0: Motor current mode;
1: Sensor mode;
2: No action
Tens place: Low speed derating
0: Action(suitable for common
motor);
1: No action(suitable for variable
frequency motor)
P9.17
Sensor protection
threshold
of motor
10.00
0.00 ~ 10.00
V × 0.00 ~ 10.00V
P9.18
Motor overload protection
time
10.0
0.5 ~ 30.0 min
× 0.5 ~ 30.0min
Group PA Control Parameter
PA.00 Carrier frequency
8.0
4.0
3.0
2.0
0.7 ~ 16.0 kHz
15kW or below : 0.7kHz ~ 16.0kHz;
18.5kW ~ 45kW: 0.7kHz ~ 10.0kHz;
55kW ~ 75kW: 0.7kHz ~ 8.0kHz;
90kW or above: 0.7kHz ~ 3.0kHz
PA.01
Carrier frequency
automatic
adjustment selection
1 0 ~ 1 /
0: No auto adjustment;
1: Auto adjustment
PA.02
Vector control 1 slip
compensation gain
100.0
0.0 ~ 300.0
% 0.0 ~ 300.0%
PA.03 Droop control 0.00
0.00 ~ 10.00
Hz 0.00 ~ 10.00Hz
PA.04
Current limit action
selection
1 0 ~ 1 / ×
0: Disabled;
1: Enabled
PA.05 Current limit value 160.0
20.0 ~ 200.0
% ×
Constant torque: 20.0 ~ 200.0%
rated current of inverter
Variable torque: 20.0 ~ 150.0%
rated current of inverter
PA.06 Voltage adjustment function
101
000 ~ 111 / ×
Ones place: Over voltage
regulation
0: Disabled; 1: Enabled
Tens place: Under voltage
regulation
0: Disabled; 1: Enabled
Hundreds place: Over
modulation
0: Disabled; 1: Enabled