High Performance Vector Control/Torque Control Inverter User Manual
68 Chapter 6 Parameter Description
Fig.6-5 Process open loop main and auxiliary reference calculation 1
Open loop combination reference f
com
=main reference f
m
-auxiliary reference f
a
2: Auxiliary reference-50%: The auxiliary reference value subtracts the bias equal to 50% of the auxiliary
reference full range value. The main reference value is invalid at this time.
Fig.6-6 Process open loop main and auxiliary reference calculation 2
Open loop combination reference f
com
=auxiliary reference f
a
-50% bias
3: Main reference + auxiliary reference-50%: The auxiliary reference value subtracts the bias equal to
50% of the auxiliary reference full range value and then superimposes on the main reference.
Frequency
Time
Frequency
Time
50%
频率
时间
100%
fa
fcom
Frequency
Time
50%
频率
时间
100%
fa
fcom
Frequency
Time