1 Product Overview
QSW-98XX series next generation core switches adopt the CLOS/ FULL MESH architecture and support large buffer.
QSW-98XX series support dual supervisor modules and power supply redundancy, and are available in three models,
namely, QSW-9805, QSW-9807 and QSW-9810.
The QSW-9805: designed with 5 transverse slots, supporting dual supervisor modules and providing 3 service
module slots;
The QSW-9807: designed with 7 transverse slots, supporting dual supervisor modules and providing 5 service
module slots;
The QSW-9810: designed with 10 vertical slots, supporting dual supervisor modules and providing 8 service module
slots.
1.1 QSW-9805
Specifications
Model
QSW-9805
Module Slot
two supervisor module slots, three service module slots
Supervisor Module
QSW-M-98XX-MC
Supervisor Module
Redundancy
Supported
Switch Fabric
Module
Not supported
Service Module
QSW-М-98XX-8XS-M
QSW-М-98XX-4XS44SFP-M
QSW-М-98XX-4XS24GT20SFP-M
QSW-М-98XX-48GT-M
QSW-М-98XX-48GT-POE-M
QSW-М-98XX-48XS-UH
QSW-М-98XX-4QXS24XS-UH
QSW-М-98XX-12QXS-UH
QSW-М-98XX-24SFP8GT-L
QSW-М-98XX-24GT8SFP-L
Hot Swapping
Supported
Power Supply
Module
QSW-M-98XX-PWR2-AC: 90 to180 VAC, power: 1200W;
180 to 264VAC, power: 1600W
QSW-M-98XX-PWR-AC: 90 to180 VAC, power: 600W:
180 to 264VAC, power: 600W
QSW-M-98XX-PWR-AC-POE1: 90 to 176 VAC, power: 1000W;
176 to 264 VAC, power: 1600W
QSW-M-98XX-PWR-AC-POE2: 90 to 176 VAC, power: 1200W;
176 to 210 VAC, power: 2500W
210 to 264 VAC, power: 3000W
QSW-M-98XX-PWR2-DC: -40.5 to -75 VDC, power: 1600W
QSW-M-98XX-PWR-DC: -40.5 to -75 VDC, power: 600W
HVDC Power
Supply
QSW-M-98XX-PWR2-AC: 192 to 216 VDC, power: 1200W;
216 to 290 VDC, power: 1600W
QSW-M-98XX-PWR-AC: 192 to 290 VDC, power: 600W
The power supply supports reversible HVDC.
The HVDC-supported PDU socket should be provided.
It is recommended to install a DC air switch. During power-on, turn on the DC air switch
after connecting the power cord. During power-off, turn off the DC air switch before