Beurer MPE 38 [10/48] What if there are problems

Beurer MPE 38 [10/48] What if there are problems
10
Important
Only insert UV-9W-L type fluorescent tubes into the device.
To replace the fluorescent tubes, follow the steps contained in section “3. Initial use”.
Cleaning
Warning
Before beginning cleaning, pull the mains plug out of the socket!
Clean the base plate after each use.
Clean the surface of the device and the base plate carefully using a slightly damp cloth only.
Do not use any cleaning agents or solvents.
6. What if there are problems?
Problem Possible cause Solution
Device will not switch
on.
Mains plug not plugged in. Insert the mains plug into the socket.
No voltage at mains socket. Check your fusebox.
UV nail gel does not dry. Treatment time with UV light too short. Set a longer UV light treatment time.
UV fluorescent tube
does not light up.
UV fluorescent tube not correctly
inserted.
Check that the UV fluorescent tube has
been correctly inserted.
UV fluorescent tube faulty. Insert a new UV fluorescent tube.
7. Replacement parts and wearing parts
Replacement parts and wearing parts are available from the corresponding service address (according to the
service address list). Please state the corresponding order number.
Designation Item number and/or order number
UV fluorescent tubes, 4 units 163.290
8. Disposal
Observe the local regulations for material disposal. Dispose of the unit in accordance with EC Directive
2002/96/EC – WEEE (Waste Electrical and Electronic Equipment). If you have any questions, please
contact the local authorities responsible for waste disposal.
9. Technical data
Model no. MPE 38
Dimensions L220 x W210 x H100 mm
Weight 1610 g (including UV fluorescent tubes)
Power supply 230 V, ~ 50 Hz
Nominal power 36 W
Permissible storage conditions Store in a clean and dry place
Number of UV lamps 4
UV lamp type UV-9 W-L 365 nm, 9 W
UV type of device UV-A lamp type 3
Switch-off times 120 seconds, continuous operation