Indesit K342 GS/R [19/60] Burner and nozzle characteristics

Indesit K342 G/R [19/60] Burner and nozzle characteristics
19
Table 1 Liquid Gas Natural Gas
Burner Diameter
(mm)
Thermal Power
kW (p.c.s.*)
By-Pass
1/100
Nozzle
1/100
Flow*
g/h
Nozzle
1/100
Flow*
l/h
Nozzle
1/100
Flow*
l/h
Nominal Reduced (mm) (mm) *** ** (mm) (mm)
Fast
(Large)(R)
100 3.00 0.7 41 86 218 214 116 286 143 286
Semi Fast
(Medium)(S)
75 1.90 0.4 30 70 138 136 106 181 118 181
Auxiliary
(Small)(A)
55 1.00 0.4 30 50 73 71 79 95 80 95
Oven - 3.10 1.0 46 85 225 221 132 295 148 288
Grill - 2.50 - - 80 182 179 122 227 139 227
Supply
Pressures
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
28-30
20
35
37
25
45
20
17
25
13
6,5
18
* At 15°C and 1013 mbar- dry gas
** Propane P.C.S. = 50,37 MJ/Kg
*** Butane P.C.S. = 49,47 MJ/Kg
Natural P.C.S. = 37,78 MJ/m
3
Table1 (For Hungary)
G 20 G 25.1 G 30
Burner By-pass
1/100 (mm)
Thermal
power kW
Nozzle
1/100 (mm)
Thermal
power kW
Nozzle
1/100 (mm)
Thermal
power kW
Nozzle
1/100 (mm)
Fast (R) 41 3,30 116 2,60 116 2,60 86
Semi Fast (S) 30 2,10 106 1,70 106 1,70 70
Auxiliary (A) 30 1,15 79 0,90 79 0,90 50
Oven 46 3,50 132 2,60 132 3,00 85
Grill - 2,60 122 2,00 122 2,40 80
Supply pressures 25 mbar 25 mbar 30 mbar
At 15°C and 1013 mbar-dry gas
P.C.I. G20 37,780 MJ/m
3
P.C.I. G30 122,8 MJ/m
3
P.C.I. G25.1 32,510 MJ/m
3
S
S
R
A
Important
On completion of the operation, replace the old rating
sticker with one indicating the new type of gas used. This
sticker is available from our Service Centres.
Burner and nozzle characteristics
Note
Should the pressure of the gas used be different (or vary)
from the recommended pressure, it is necessary to fit a
suitable pressure regulator onto the inlet pipe in
compliance with current National Regulations relative to
“regulators for channelled gas”.
K 342 G/R
K 342 GB/R
K 342 GS/R
K 343 GS/R

Содержание

Похожие устройства

Important On completion of the operation replace the old Note Should the pressure of the gas used be different or vary from the recommended pressure it is necessary to fit a suitable pressure regulator onto the inlet pipe in compliance with current National Regulations relative to regulators for channelled gas rating sticker with one indicating the new type of gas used This sticker is available from our Service Centres Burner and nozzle characteristics Table 1 Burner Liquid Gas Diameter mm Thermal Power kW p c s By Pass 1 100 Nozzle 1 100 116 286 143 286 30 70 138 136 106 181 118 181 0 4 30 50 73 71 79 95 80 95 3 10 1 0 46 85 225 221 132 295 148 288 2 50 80 182 179 122 227 139 227 28 30 20 35 37 25 45 3 00 0 7 41 75 1 90 0 4 55 1 00 Oven Grill Supply Pressures Flow l h 214 100 Small A Nozzle 1 100 218 mm Auxiliary Flow l h 86 mm Medium S Nozzle 1 100 Reduced Semi Fast Flow g h Nominal Fast Large R Natural Gas Nominal mbar Minimum mbar Maximum mbar mm mm 20 17 25 13 6 5 18 At 15 Cand 1013 mbar dry gas Propane P C S 50 37 MJ Kg Butane P C S 49 47 MJ Kg Natural P C S 37 78 MJ m3 Tablel For Hungary G 20 G 25 1 G 30 Burner By pass 1 100 mm Thermal power kW Nozzle 1 100 mm Thermal power kW Nozzle 1 100 mm Thermal power kW Nozzle 1 100 mm Fast R 41 3 30 116 2 60 116 2 60 86 Semi Fast S 30 2 10 106 1 70 106 1 70 70 Auxiliary A 30 1 15 79 0 90 79 0 90 50 Oven 46 3 50 132 2 60 132 3 00 85 2 60 122 2 00 122 2 40 80 Grill 25 mbar Supply pressures 25 mbar At 15 C and 1013 mbar dry gas P C I G20 37 780 MJ m3 P C I G30 P C I G25 1 K 342 G R K 342 GB R K 342 GS R K 343 GS R 19 122 8 MJ m3 32 510 MJ m3 30 mbar