Daikin EWWDC11CJYNN [165/180] Partial heat recovery ratings ewwd340 c19cjynn

Daikin EWWDC11CJYNN [165/180] Partial heat recovery ratings ewwd340 c19cjynn
ESIE07-05 Appendix A
Part 5 – Maintenance 6–11
3
5
1
6
1.9 Partial Heat Recovery Ratings EWWD340-C19CJYNN
Unit
Leaving des-
uperheaters
water temper-
atur
Entering condenser water temperature °C
30 35 40 45 50
Heating
capacity (kW)
Heating
capacity (kW)
Heating
capacity (kW)
Heating
capacity (kW)
Heating
capacity (kW)
340
40
45
50
43.7
39.3
35.8
69.4
62.5
56.9
92.8
83.6
76.1
114.7
103.4
94.0
135.2
121.8
110.8
400
40
45
50
51.6
46.5
42.3
82.1
73.9
67.3
110.0
99.1
90.2
135.6
122.2
111.2
159.9
144.1
131.1
480
40
45
50
59.6
53.7
48.8
95.2
85.8
78.1
127.5
114.9
104.5
158.5
142.8
130.0
187.4
168.9
153.7
550
40
45
50
65.4
58.9
53.6
104.3
93.9
85.5
139.9
126.0
114.7
173.0
155.8
141.8
204.0
183.8
167.3
700
40
45
50
87.1
78.5
71.4
138.6
124.9
113.7
185.3
167.0
151.9
229.1
206.4
187.9
269.7
243.0
221.1
750
40
45
50
95.5
86.1
78.3
152.0
136.9
124.6
203.3
183.1
166.6
251.2
226.3
205.9
296.2
266.8
242.8
800
40
45
50
102.5
92.3
84.0
163.1
146.9
133.7
218.2
196.6
178.9
270.0
243.3
221.4
318.4
286.8
261.0
900
40
45
50
112.4
101.3
92.2
178.8
161.1
146.6
239.6
215.9
196.5
296.5
267.1
243.1
350.5
315.8
287.4
950
40
45
50
120.3
108.4
98.6
191.6
172.6
157.1
256.9
231.4
210.6
319.2
287.5
261.6
377.0
339.6
309.1
C10
40
45
50
139.7
125.9
114.5
222.4
200.4
182.3
297.2
267.8
243.7
367.4
331.0
301.2
432.8
389.9
354.8
C11
40
45
50
147.7
133.1
121.1
234.9
211.6
192.6
314.0
282.9
257.4
388.6
350.1
318.6
457.5
412.1
375.0
C12
40
45
50
155.9
140.4
127.8
247.7
223.1
203.1
331.0
298.2
271.4
409.8
369.1
335.9
482.5
434.7
395.6
C13
40
45
50
163.8
147.5
134.3
260.5
234.7
213.6
348.7
314.2
285.9
431.8
389.0
354.0
509.7
459.2
417.9
C14
40
45
50
171.8
154.8
140.8
273.3
246.2
224.1
366.0
329.7
300.0
454.2
409.2
372.3
536.5
483.4
439.9
C15
40
45
50
179.6
161.8
147.2
286.3
258.0
234.7
383.7
345.7
314.6
476.2
429.0
390.4
563.4
507.5
461.9

Содержание

Скачать