Daikin FXHQ32MVET [353/370] Fxmq20p 25p 32p 40p 50p 63p 80p 100p 125p 140pve

Daikin FXSQ50PVE4 [353/370] Fxmq20p 25p 32p 40p 50p 63p 80p 100p 125p 140pve
SiBE311209 Wiring Diagrams for Reference
Appendix 344
FXMQ20P / 25P / 32P / 40P / 50P / 63P / 80P / 100P / 125P / 140PVE
3D058783E
R3
-
X70A
N=1
X10A
RED
BLU
PS
GRN/YLW
A3P
P1
GRN
WHT
X35A
BLU
YLW
WHT
Z3C
WIRED REMOTE
CONTROLLER (OPTIONAL
ACCESSORY)
X15A
X30A
F4U
X28A
V1R
X25A
+
X3A
R4
ORG
X10A
WHT
L
KPR
YLW
X7A
P2
R4T
+
R1T
N=8
YLW
R2T
-
RED
POWER
SUPPLY
L
BLK
BLU
TRANSMISSION
WIRING
CENTRAL REMOTE
CONTROLLER NOTE) 2
R1
C1
BLU
X1A
X1M
TO X1M
TO X70A (A1P)
X6A
M1P
M1F
HAP
YLW
HAP
X3A
F2
MS
3~
HAP
P2
K1R
R3T
X8A
Y1E
A2P
R1T
MS
3~
-t˚
GRY
NOTES)
~220-240V
50Hz
~220V
60Hz
L1R
SS1
L1R
RED
C3
GRN
5
X16A
N
K1R
S1L
FOR FXMQ50 · 63 · 80 · 100 · 125 · 140PVE
PNK
R2
V1R
X27A
BLK
M
~
T2
-
BLU
F3U
NOTE) 5
P1
* ONLY FXMQ50 · 63 · 80 · 100 · 125 · 140PVE
R5T
Z1C
X9A
A2P
+
X2M
X1M
Z2C
L1R
A2P
X28A
X33A
X35A
C1
C2
X6A
X17A
BLU
RED
N
X33A
X18A
F1U
FOR FXMQ20 · 25 · 32 · 40PVE
M1F
Z1F
Z2C
GRN
A1P
M
+
-
F2U
EL.COMPO.BOX (INDOOR)
T1
X13A
V2R
INPUT FROM
OUTSIDE NOTE) 3
BLK
BLK
ORG
BRN
X2M
X2A
F1
Z1F
PNK
R2
ORG
RED
PS
PS
A
1
P
A
3
P
Z
1
C
*
A1P
R1T
R2T
R3T
R4T
R5T
S1L
V1R
V2R
X1M
X2M
Z1F
X28A
X33A
X35A
R1T
SS1
Y1E
Z1C
Z2C
Z3C
A2P
A3P
F1U
F2U
F3U
F4U
HAP
KPR
K1R
L1R
M1F
M1P
PS
R1
R2
R3, R4
C1, C2, C3
INDOOR UNIT
PRINTED CIRCUIT
BOARD
PRINTED CIRCUIT
BOARD (FAN)
PRINTED CIRCUIT
BOARD (CAPACITOR)
FUSE (T. 3.15A, 250V)
FUSE (T. 5A, 250V)
FUSE (T. 6.3A, 250V)
FUSE (T. 6.3A, 250V)
CAPACITOR
LIGHT EMITTING DIODE
(SERVICE MONITOR-GREEN)
(A1P, A2P)
MAGNETIC RELAY
MAGNETIC RELAY
REACTOR
MOTOR (FAN)
SWITCHING POWER
SUPPLY (A1P, A2P)
RESISTOR
(CURRENT LIMITING)
CURRENT
SENSING DEVICE
RESISTOR
(ELECTRIC DISCHARGE)
MOTOR (DRAIN PUMP)
TERMINAL STRIP
(CONTROL)
THERMISTOR
(DISCHARGE AIR)
CONNECTOR
(FOR WIRING)
NOISE FILTER
TERMINAL STRIP
(POWER SUPPLY)
THERMISTOR (AIR)
WIRED REMOTE CONTROLLER
CONNECTOR OPTIONAL
ACCESSORY
ELECTRONIC
EXPANSION VALVE
THERMISTOR (GAS)
NOISE FILTER
(FERRITE CORE)
CONNECTOR (POWER
SUPPLY FOR WIRING)
CONNECTOR (ADAPTER)
DIODE BRIDGE
THERMISTOR (SUCTION AIR)
THERMISTOR (LIQUID)
FLOAT SWITCH
THERMISTOR NTC
(CURRENT LIMITING)
SELECTOR SWITCH
(MAIN/SUB)
POWER MODULE
1. : TERMINAL : CONNECTOR : FIELD WIRING
2. IN CASE USING CENTRAL REMOTE CONTROLLER, CONNECT IT TO THE UNIT IN
ACCORDANCE WITH THE ATTACHED INSTALLATION MANUAL.
3. WHEN CONNECTING THE INPUT WIRES FROM OUTSIDE, FORCED OFF OR ON/OFF
CONTROL OPERATION CAN BE SELECTED BY REMOTE CONTROLLER.
IN DETAILS, REFER TO THE INSTALLATION MANUAL ATTACHED THE UNIT.
4. COLORS BLK : BLACK RED : RED BLU : BLUE WHT : WHITE PNK : PINK YLW : YELLOW
BRN : BROWN GRY : GRAY GRN : GREEN ORG : ORANGE.
5. FOR FXMQ50 · 63 · 80 · 100 · 125 · 140PVE, N=2.

Содержание

Скачать