Daikin FXHQ32MVET [4/370] Troubleshooting by indication on the remote controller 08

Daikin FXSQ140PVE [4/370] Troubleshooting by indication on the remote controller 08
SiBE311209
iii Table of Contents
Part 6 Service Diagnosis........................................................... 187
1. Check Items for Service ......................................................................189
1.1 For Troubleshooting .............................................................................189
1.2 Precautions for Service ........................................................................189
2. Symptom-based Troubleshooting .......................................................191
3. Troubleshooting by Remote Controller ...............................................194
3.1 The INSPECTION / TEST Button.........................................................194
3.2 Self-diagnosis by Wired Remote Controller .........................................195
3.3 Self-diagnosis by Wireless Remote Controller .....................................196
3.4 Remote Controller Service Mode .........................................................197
3.5 Inspection Mode...................................................................................199
3.6 Test Run Mode.....................................................................................200
3.7 Remote Controller Self-Diagnosis Function .........................................200
3.8 List of Error Code .................................................................................202
4. Troubleshooting by Indication on the Remote Controller ....................208
4.1 Error of External Protection Device ......................................................208
4.2 Indoor Unit PCB Defect ........................................................................209
4.3 Drain Level Control System (S1L) Abnormality....................................210
4.4 Fan Motor (M1F) Lock, Overload .........................................................212
Indoor Unit Fan Motor Abnormality ......................................................214
4.5 Swing Flap Motor (M1S) Abnormality...................................................218
4.6 Electronic Expansion Valve Abnormality / Dust Clogging ....................220
Electronic Expansion Valve Coil Abnormality.......................................222
4.7 Drain Level above Limit........................................................................223
4.8 Capacity Determination Device Abnormality ........................................224
4.9 Heat Exchanger Thermistor (R2T) Abnormality ...................................225
4.10 Gas Pipes Thermistor (R3T) Abnormality ............................................226
4.11 Suction Air Thermistor (R1T) Abnormality............................................227
4.12 Discharge Air Thermistor (R4T) Abnormality .......................................228
4.13 Room Temperature Thermistor in Remote Controller Abnormality ......229
4.14 PCB Defect...........................................................................................230
4.15 High Pressure Switch Abnormality .......................................................231
4.16 Low Pressure Sensor Abnormality .......................................................233
4.17 Inverter Compressor Motor Lock..........................................................235
4.18 STD Compressor Motor Overcurrent/Lock...........................................237
4.19 Outdoor Unit Fan Motor Abnormality....................................................238
4.20 Electronic Expansion Valve Coil (Y1E~Y3E) Abnormality....................241
4.21 Discharge Pipe Temperature Abnormality ...........................................243
4.22 Refrigerant Overcharged......................................................................245
4.23 Abnormal Outdoor Unit Fan Motor Signal ............................................246
4.24 Outdoor Air Thermistor (R1T) Abnormality...........................................248
4.25 Current Sensor Abnormality .................................................................249
4.26 Discharge Pipe Thermistor (R31T, R32T, R33T) Abnormality .............250
4.27 Heat Exchanger Gas Pipe Temperature Thermistor (R2T)..................251
4.28 Suction Pipe Thermistor (R8T) Abnormality.........................................252
4.29 Outdoor Unit Heat Exchanger Thermistor (R4T)..................................253
4.30 Liquid Pipe Thermistor 1 (R6T or R9T) Abnormality ............................254
4.31 Liquid Pipe Thermistor 2 (R7T) Abnormality ........................................255
4.32 Subcooling Heat Exchanger Gas Pipe Thermistor (R5T)
Abnormality ..........................................................................................256
4.33 High Pressure Sensor Abnormality ......................................................257

Содержание

Скачать