Daikin FXDQ50NVE [196/218] Grn ylw

Daikin FXDQ50NVE [196/218] Grn ylw
SiBE39-402 Wiring Diagrams for Reference
Appendix 187
2. Wiring Diagrams for Reference
2.1 Outdoor Unit
RXYSQ4M7V3B
RXYSQ5M7V3B
RXYSQ6M7V3B
L1R
L
N
A2P
A3P
U
YLW
V1T
N
P2
P1
P3
P4
-
W
V2R
V
E1
+
C2
Z1C
K1M
X1M
RED
LB
LC
RED
LA
M1C
+
+
U
U
L
RED
N
V
V
3~
MS
R1
+
+
WHT
Z1F
GRN/YLW
C3
C1
W
W
K2R
F1U
BLU
NB
BLU
R2
BLU
NC
NA
N
-
N
-
BRN
N=5
V1R
M1F
X1A
Z2C
WHT
(
RED MARKING
)
3~
MS
PS
X206A
RED
RED
RED
X60A
M2F
Z3C
3~
MS
S1PH
P<
X207A
HAP
WHT
WHT
WHT
WHT
X205A
RED
BLU
X1A
A1P
X25A
1
R3T
Y1S
Cool
X2A
X1M
A
X34A
K1R
Y2S
X3A
S2S
Heat
B
K2R
Cool
Heat
1
R2T
C
Fan
S1S
Y3S
X5A
TO IN/D UNIT
R4T
F1
K4R
E1HC
F2
X6A
indoor
(
F1
)(
F2
)
X37A
R5T
TO OUT/D UNIT
F1
HAP
X22A
BS1
K5R
H1P
F2
BS2
OFF
OFF
H2P
ON
ON
H3P
BS3
1
1
H4P
T1R
DS2
DS1
2
2
H5P
3
3
BS4
H6P
4
4
H7P
BS5
X23A
Front
A1P
X26A
X28A
X45A
X46A
X44A
X1M
NOTE
)
4
A3P
X24A
X1M
A
S1NPL
S1NPH
6
6
L1R
Y2E
R1T
Y1E
A2P
M
M
View A
3D044946B
A3P
K4R
K2R
HAP
HAP
K2R
A2P
K5R
R2
M2F
E1HC
R2T
R3T
R5T
R4T
BS1~5
Y2E
Y2S
Y3S
S2S
H1P~7P
F1U
K1R
A1P
K1M
L1R
V1T
PS
R1
S1NPL
S1PH
V1R
,
V2R
M1C
M1F
R1T
S1NPH
Z1C~3C
Y1S
T1R
Y1E
S1S
X1M
X1M
DS1
,
2
C1
,
2
,
3
L-RED
N-BLU
Z1F
+
Power supply
230V~50Hz
The position
of compressor
terminal
The entrance
of wire
C/H Selector
Note 8
outdoor
(F1)(F2)
C/H Selector (Optional accessory)
Notes
Printed circuit board (Main)
Printed circuit board (Inv)
Printed circuit board (Noise filter)
Push button switch
(Mode, set, return, test, reset)
Capacitor
Dip switch
Crankcase heater
Fuse (T 6.3A/250V)
Pilot lamp (Service monitor-orange)
[H2P] Prepare, test------flickering
Malfunction detection----light up
Pilot lamp (Service monitor-green) (A1P)
Pilot lamp (Service monitor-green) (A2P)
Magnetic contactor (M1C)
Magnetic relay (K1M)
Magnetic relay (Y1S)
Magnetic relay (Y2S)
Magnetic relay (Y3S)
Magnetic relay (E1HC)
Reactor
Motor (Compressor)
Motor (Fan)
Motor (Fan)
Switching power supply
Resistor (Current limiting)
Resistor (Current sensor)
Thermistor (Air)
Thermistor (Suction)
Thermistor (M1C discharge)
Thermistor (Heat exc. deicer)
Thermistor (Heat exc. outlet)
Pressure s
ensor (High)
Pressure sensor (Low)
Pressure switch (High)
Transformer (230V/24V)
Power modeule (A2P)
IGBT (A2P)
Te rm in al strip (Power Supply)
Te rm in al strip (Control) (A1P)
Electronic expansion valve (Main)
Electrionic expansion valve (Sub cool)
Solenoid valve (Hot gas)
Solenoid valve (Receiver gas purge) solenoid valve
Solenoid valve (4 way valve)
Noise filter (Ferrite core)
Noise filter (With surge absorber)
C/H selector (KRC 19-26A)
Selector switch (Fan/Cool
·Heat)
Selector switch (Cool/Heat)
1. This wiring diagram is applied only to the outdoor unit.
2. : Field wiring.
3. : Terminal strip : Movable connector :Fixed connector
: Terminal : Protective earth (Screw) : Noiseless earth
4. When using the option adapter, refer to the installation manual.
5. Refer to Operation caution label (On back of front plate), how to use
BS1~BS5 and DS1·2 switch.
6. When operating, dont short circuit for protection device. (S1PF)
7. Colors BLU: blue, BRN:
brown, GRN: green, RED: red, WHT: white,
YLW: yellow.
8. Refer to the installation manual, for connection wiring to indoor-
outdoor transmissions F1·F2, outdoor-outdoor transmission F1·F2

Содержание

Скачать