Daikin FXDQ50NVE [198/218] Fxdq20n 25n 32n 40n 50n 63nve

Daikin FXDQ50NVE [198/218] Fxdq20n 25n 32n 40n 50n 63nve
SiBE39-402 Wiring Diagrams for Reference
Appendix 189
FXDQ20N / 25N / 32N / 40N / 50N / 63NVE
FXMQ40M / 50M / 63M / 80M / 100M / 125MVE
Z2C
Z1C
X1M
L
N
X18A
A1P
C1
T1R
X2M
X16A
Y1E
X2M
M
L
N
S1L
RED
GRN
/YLW
BLU
X31A
X7A
X8A
X13A
R1T
F1U
X25A
KPR
X12A
X1A
R2T
T1R
R3T
X11A
M1P
~
M
X3A
HAP
X16A
V1TR
X18A
X30A
X27A
A1P
X4A
PRP
BLK
RED
BLU
GRY
N=3
N=3
Z2C
Z1C
YLW
C1
WHT
YLW
ORG
BLK
BLU
PNK
WHT
X1M
P2
F2
T2
T1
F1
P1
M1F
~
M
Q1M
SS1
P2
P1
R1T
3D045500A
220-240V
50Hz
~
220V
60Hz
~
X18A
X16A
V1TR
Z1C Z2C
C1
S1L
Q1M
X1M
X2M
F1U
HAP
R1T
R3T
A1P
Y1E
R2T
SS1
R1T
M1F
M1P
KPR
T1R
Power Supply
Control box
Wired remote
control
Note 5
Input from outside
Transmission
wiring central
remote control
Note 3
Printed circuit board
Capacitor (M1F)
Fuse (F5A/250V)
Light emitting diode
(Service monitor green)
Magnetic relay (M1P)
Motor (Indoor fan)
Motor (Drain pump)
Thermal protector (M1F embedded)
Thermistor (Air)
Thermistor (Coil-1)
Thermistor (Coil-2)
Float switch
Transformer (220V/22V)
Phasecontrol circuit
Terminal block
Terminal block
Electronic expansion valve
Noise filter (Ferrite core)
Thermistor (Air)
Selector switch (Main/Sub)
Connector (Adapter for wiring)
Connector (Wiring adapter for
electrical appendices)
Wired remote control
Connector for optional parts
Notes
1. : Terminal
: Connector
2. : Field wiring
3. In case using central remote control, connect it to the unit in accordance with the atta
ched instruction manual.
4. Remote control model varies according to the combination system, confirm engineering materials and catalogs, etc. before connecting.
5. When connecting the input wires from outside, forced OFF or ON/OFF control operation can be selected by remote control.
In details, refer to the installation manual attached the unit.
6. Symbosl show as follows: RED: red, BLK: black, WHT: white, YLW: yellow, PRP: purple, GRY: gray, BLU:
blue, PNK: pink, ORG: orange, GRN: green)
A2P
X4A
YC
FC
RED
RED
X3A
BLK
FH
BLK
BLU
X2A
ORG
FL
ORG
BRN
X1A
LL
FLL
BRN
T1R
220-240V
50Hz
~
A1P
X3A
X1A
X1M
220V
60Hz
~
F1U
A2P
L
X4A
RED
L
YC
N
WHT
FC
RED
N
C1R
WHT
YLW
RED
X3A
BLK
FH
K1R
BLK
M
~
X13A
BLU
R1T
Q1M
M1F
X2A
K2R
ORG
FL
ORG
X12A
R2T
BRN
X1A
LL
K3R
FLL
BRN
R3T
X11A
HAP
Y2
M1P
~
M
X8A
S1L
Y1
KPR
X7A
Y1E
X18A
M
F2
T2
P2
F1
T1
P1
X30A
WHT
PNK
BLK
YLW
WHT
BLU
ORG
X2M
T2
F2
T1
P2
F1
P1
X18A
R1T
P1
T1R
P2
A1P
SS1
C1R
A2P
X2M
X1M
3D039620A
,
K1R-K3R
Q1M
C1R
HAP
M1F
F1U
KPR
F1U
A2P
A1P
R2T·R3T
M1P
S1L
R1T
T1R
X18A
X1M
X2M
Y1E
R1T
SS1
Power supply
Note 5
Note 4
Input from outside
Note 3
Transmission wiring
central remote control
Indoor unit
Optional parts
Connector for optional parts
Wired remote control
Printed circuit board
Terminal board
Capacitor (M1F)
Fuse (B 5A, 250V)
40·50·63·80 type
Fuse (B, 10A, 250V)
100·125 type
Light emitting
diode (Service
monitor green)
Magnetic relay
(M1F)
Magnetic relay
(M1P)
Motor (Indoor fan)
Thermo switch
(M1F embedded)
Thermistor (Air)
Thermistor (Coil)
Float switch
Transformer
(220-240V/22V)
Te rmi nal block (Power)
Terminal block (Control)
Electronic expansion
valve
Motor (Drain pump)
Selector switch
(Main/Sub)
Thermistor (Air)
Connector (Wiring adapter
for electorical appendices)
Notes
1. : Terminal block, : Connector, : Terminal
2. : Field wiring
3. In case using central remote control, connect it to the unit in accordance with the attached
instruction manual.
4. When connecting the input wires from outside, forced OFF or ON/OFF control operation can be
selected by remote control.
In details, refer to the installation manual attached the unit.
5. In case high E.S.P. operation, change the wiring connection of X2A as shown upper figure.
6. Symbols s
how as follows. (PNK: pink, WHT: white, YLW: yellow, ORG: orange, BLU: blue, BLK:
black, RED: red, BRN: brown)
7. Use copper conductors only.
Electric parts box
Wired remote control
(Optional accessory)

Содержание

Скачать